These state-of-the-art personal gas monitor used to alert users of hazardous gases in their work area. Features a housing that is made of a field-proven polycarbonate with a permanent rubber-like protective outer covering.
These state-of-the-art personal gas monitor used to alert users of hazardous gases in their work area. Features a housing that is made of a field-proven polycarbonate with a permanent rubber-like protective outer covering.
These meters offer a user-friendly design, a large graphic display, and 3 types of alarms; audible, visual and vibration. Calibration is easy to complete manually or with the optional SCAL-400 calibration and charging station.
Features
Easy to get started
Available Gas Sensors
Applications
Methane (CH4) | |
Resolution | 0.1% |
Range | 0 to 100% LEL |
Accuracy | ±10% |
Response T90 Times | < 10 Seconds |
Chlorine (Cl2) | |
Resolution | 0.1% |
Range | 0 to 30ppm |
Accuracy | ±1ppm or 10% (whichever is greater) |
Oxygen (O2) | |
Resolution | 0.1% |
Range | 25% |
Accuracy | ±2 of reading or 10% (whichever is greater) |
Response T90 Times | < 10 Seconds |
Carbon Monoxide (CO) | |
Resolution | 1ppm |
Range | 0 to 999ppm |
Accuracy | ±5ppm or 10% (whichever is greater) |
Response T90 Times | < 10 Seconds |
Hydrogen Sulfide (H2S) | |
Resolution | 1ppm |
Range | 0 to 100ppm |
Accuracy | ±2ppm or 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Hydrogen Cyanide (HCN) | |
Resolution | 0.1ppm |
Range | 0 to 250ppm |
Accuracy | ±1ppm or 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Nitrogen Dioxide (NO2) | |
Resolution | 1ppm |
Range | 0 to 250ppm |
Accuracy | ±2ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Phosphine (PH3) | |
Resolution | 0.1ppm |
Range | 0 to 10ppm |
Accuracy | ±1ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Sulfur Dioxide (SO2) | |
Resolution | 0.1ppm |
Range | 0 to 20ppm |
Accuracy | ±1ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Ethylene Oxide (ETO) | |
Resolution | 0.1ppm |
Range | 0 to 10ppm |
Accuracy | ±1ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
General Specifications | |
Dimensions | 5.2 x 3.2 x 1.7" (13.2 x 8.1 x 4.0cm) |
Weight | 12oz (340g) |
Operational Temperature | -4 to 122°F (-20 to 50°C) |
Power Supply | 4 x "AA" Alkaline or NiMH Recharger Pack |
Battery Life | 24hr Alkaline or 15hr NiMH |
Typical Response Time | Initial: < 2 Seconds T90: < 10 Seconds (LEL) |
Sound | 98db at 15cm |
Click on a category to view a selection of compatible accessories with the SENSIT P400 Series Personal Gas Monitors.
Methane (CH4) | |
Resolution | 0.1% |
Range | 0 to 100% LEL |
Accuracy | ±10% |
Response T90 Times | < 10 Seconds |
Chlorine (Cl2) | |
Resolution | 0.1% |
Range | 0 to 30ppm |
Accuracy | ±1ppm or 10% (whichever is greater) |
Oxygen (O2) | |
Resolution | 0.1% |
Range | 25% |
Accuracy | ±2 of reading or 10% (whichever is greater) |
Response T90 Times | < 10 Seconds |
Carbon Monoxide (CO) | |
Resolution | 1ppm |
Range | 0 to 999ppm |
Accuracy | ±5ppm or 10% (whichever is greater) |
Response T90 Times | < 10 Seconds |
Hydrogen Sulfide (H2S) | |
Resolution | 1ppm |
Range | 0 to 100ppm |
Accuracy | ±2ppm or 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Hydrogen Cyanide (HCN) | |
Resolution | 0.1ppm |
Range | 0 to 250ppm |
Accuracy | ±1ppm or 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Nitrogen Dioxide (NO2) | |
Resolution | 1ppm |
Range | 0 to 250ppm |
Accuracy | ±2ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Phosphine (PH3) | |
Resolution | 0.1ppm |
Range | 0 to 10ppm |
Accuracy | ±1ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Sulfur Dioxide (SO2) | |
Resolution | 0.1ppm |
Range | 0 to 20ppm |
Accuracy | ±1ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
Ethylene Oxide (ETO) | |
Resolution | 0.1ppm |
Range | 0 to 10ppm |
Accuracy | ±1ppm to 10% (whichever is greater) |
Response T90 Times | < 20 Seconds |
General Specifications | |
Dimensions | 5.2 x 3.2 x 1.7" (13.2 x 8.1 x 4.0cm) |
Weight | 12oz (340g) |
Operational Temperature | -4 to 122°F (-20 to 50°C) |
Power Supply | 4 x "AA" Alkaline or NiMH Recharger Pack |
Battery Life | 24hr Alkaline or 15hr NiMH |
Typical Response Time | Initial: < 2 Seconds T90: < 10 Seconds (LEL) |
Sound | 98db at 15cm |
Click on a category to view a selection of compatible accessories with the SENSIT P400 Series Personal Gas Monitors.