SENSIT 913-00000-11 Hydrogen Cyanide Gas Analyzer, 100ppm HCN

Model: HCN | Order No: 913-00000-11

SENSIT 913-00000-11 Hydrogen Cyanide Gas Analyzer, 100ppm HCN

Model: HCN | Order No: 913-00000-11

Monitors and warns of dangerous levels of Hydrogen Cyanide. Ideal for testing ambient air and hot gas samples.

Monitors and warns of dangerous levels of Hydrogen Cyanide. Ideal for testing ambient air and hot gas samples.

Sale Price $1106.75 USD
Regular Price $1165.00 USD
Availability 1 to 2 Weeks
Quantity

SENSIT 913-00000-11 Offers

Ideal for testing ambient air and hot gas samples during post-fire clean-up. The instrument features a powerful pump, flue probe with water trap, and audible and visual alarms.

The infrared communication window allows you to easily print test results to an optional printer or transfer the data to a PC.

Features

  • Backlit Display
  • Audible/Visual Alarms
  • Push Button Operation
  • Internal Pump
  • Water/Dust Filter
  • Date/Time Display
  • Operation Memory
  • Calibration Memory
  • Calibration Alert
  • Field Calibration
  • Infrared Data Download
  • Programmable Auto Shut Off

Applications

  • Ambient Air Safety Checks
  • Fire Service Overhaul Operations

Easy to get started

  1. Press Power
  2. Wait 45 Seconds for Automatic Zeroing
  3. Begin to Use
View the Quick Start Guide for More Details

HCN Effects on Humans
HCN can cause rapid death due to metabolic asphyxiation. Death can occur within minutes or seconds when Hydrogen Cyanide gas is inhaled in high concentrations.

HCN effects on humans

SENSIT 913-00000-11 Specifications

Hydrogen Cyanide (HCN)
Resolution 1ppm
Range 0 to 100ppm
Accuracy ±2ppm or 3% (whichever is greater)
General Specifications
Dimensions 3 x 10 x 2.4" (7.6 x 25.4 x 6cm)
Weight 1.1lbs (0.5kg)
Operational Temperature -4 to 104°F (-20 to 40°C
Battery Life Alkaline: Approximately 30hrs continuous
Click here for complete specifications on the SENSIT HCN

What's included with the SENSIT 913-00000-11

  • Hydrogen Cyanide Gas Analyzer
  • Hard Carrying Case
  • 3 x "C" Batteries
  • Hot Air Probe
  • 5 Foot Flexible Tubing
  • Particle Filter
  • Instruction Manual

Click on a category to view a selection of compatible accessories with the SENSIT 913-00000-11 Hydrogen Cyanide Gas Analyzer, 100ppm HCN.

SENSIT 750-00015 Instruction Manual, HCN 750-00015
This manual will give you further details and instruction on the toxic gas analyzer.




SENSIT 872-00001 Hard Carrying Case for SENSIT Meters 872-00001
This hard plastic carrying case is for use with the SENSIT Gold G2, HXG-3, CO, and HCN. Features dimensions of 5-1/2 x 10 x 13" (13.97 x 25.4 x 33.02cm).




SENSIT 873-00003 Moisture Filter Tube for SENSIT Meters 873-00003
Blue Drierite Desiccant. For use with the SENSIT Gold G2, CO, HCN, and Trak-It IIIa.




SENSIT 873-00005 Dirt and Water Filter Assembly for the CO & HCN 873-00005
For use with the SENSIT CO Combustible Carbon Monoxide Analyzer and HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 873-00017 External Hydrophobic Filter 873-00017
For use with the SENSIT CO Combustible Carbon Monoxide Analyzer and HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 873-00008 Calibration Cartridge for SENSIT Dirt and Water Filters 873-00008
For use with SENSIT Dirt and Water Filter Assemblies, for the Gold G2, CO, HCN, and Trak-It IIIa.




SENSIT 880-00006 Gas Regulator with Adapter Assembly for SENSIT Meters, 0.5Lpm 880-00006
Features a flow rate of 0.5Lpm. The Constant Flow Valve is made out of Stainless Steel. For use with the SENSIT Gold G2, HXG-3, P400, HCN, and Trak-It IIIa.




SENSIT 880-00044 Calibration Adapter for SENSIT Meters 880-00044
For use with the SENSIT Gold G2, HXG-3, P400, HCN, and Trak-It IIIa. Compatible with CH4, CO, H2S, and HCN gasses. Includes a Luer and Tubing.




SENSIT 880-00060 Calibration Gas Regulator for 34, 58, 103, 116L Cylinders 880-00060
For use with the SENSIT Gold G2, HXG-3, P400, CO, HCN, and Trak-It IIIa.




SENSIT 881-00057 Calibration Gas Kit for the HCN, 10ppm HCN, 34L 881-00057
Includes a 34L cylinder of 10ppm Hydrogen Cyanide in Nitrogen gas, a regulator, and hose. For use with the SENSIT HCN Hydrogen Cyanide Gas Analyzer




SENSIT 881-00058 Calibration Kit for the HCN with 2 Cylinders, 100ppm CO and HCN, 34L 881-00058
Includes a 34L cylinder of 10ppm of Carbon Monoxide, a 34L cylinder of Hydrogen Cyanide in Nitrogen gas, a regulator, and hose. For use with the SENSIT HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 883-00023 Hot Air Probe for SENSIT Meters, 47-7/8" 883-00023
This hot air probe is for use with the SENSIT Gold G2, CO, and HCN. Features a diameter of 1-5/8" (4.12cm) and a length of 47-7/8" (121.602cm). Includes hose assembly.




SENSIT 871-00006 Battery Charger with Batteries for SENSIT Meters 871-00006
For use with the SENSIT HXG-3, CO, and HCN.




SENSIT 870-00040 SmartLink Software for SENSIT Meters 870-00040
Does not include IR Link. For use with the SENSIT Gold G2, HXG-3, P400, CO, HCN, and Trak-It IIIa. Works with Windows XP, Windows Vista, and Windows 7.




SENSIT 870-00004 Infrared Printer for SENSIT Meters 870-00004
Features a wireless infrared interface to print saved data for the SENSIT Gold G2, HXG-3, CO, HCN, and Trak-It IIIa.




SENSIT 870-00005 Printer Paper for the 870-00004, Pack of 6 870-00005
Pack of 6 rolls of printer paper, for use with the SENSIT 870-00004 Infrared Printer.




SENSIT 870-00006 Printer Paper for the 870-00004, Single 870-00006
Single pack of printer paper, for use with the SENSIT 870-00004 Infrared Printer.




SENSIT 870-00038 SmartLink IR Link for SENSIT Meters 870-00038
Does not include SmartLink Software. For use with the SENSIT Gold G2, HXG-3, CO, HCN, and Trak-It IIIa.




SENSIT 870-00039 SmartLink IR Link and Software for SENSIT Meters 870-00039
For use with the SENSIT Gold G2, HXG-3, CO, HCN, and Trak-It IIIa. Includes Software, Cable, IR Link, and Installation Guide. Works with Windows XP, Windows Vista, and Windows 7.




SENSIT 315-100001 Calibration Gas for the P100 & HCN, 100ppm CO, 34L 315-100001
Calibration gas mixture of 100ppm Carbon Monoxide in Air. Cylinder has a 34L capacity, and is made of aluminum. Cylinder has a maximum pressure of 985psi and an accuracy of ±10%. Cylinder has a C-10 connection. For use with the SENSIT P100 Single Gas Personal Monitor and HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 315-100006 Calibration Gas, 10ppm HCN, 34L 315-100006
Calibration gas mixture of 10ppm Hydrogen Cyanide in Nitrogen. Cylinder has a 34L capacity, and is made of aluminum. Cylinder has a maximum pressure of 985psi and an accuracy of ±10%. Cylinder has a 5/8"-18 UNF Threaded Collar connection. For use with the SENSIT Gold G2, P100, P400, HCN, and Trak-It IIIa.




Ask a question about SENSIT 913-00000-11 Hydrogen Cyanide Gas Analyzer, 100ppm HCN

Customer Reviews for the SENSIT HCN

SENSIT 913-00000-11 Offers

Ideal for testing ambient air and hot gas samples during post-fire clean-up. The instrument features a powerful pump, flue probe with water trap, and audible and visual alarms.

The infrared communication window allows you to easily print test results to an optional printer or transfer the data to a PC.

Features

  • Backlit Display
  • Audible/Visual Alarms
  • Push Button Operation
  • Internal Pump
  • Water/Dust Filter
  • Date/Time Display
  • Operation Memory
  • Calibration Memory
  • Calibration Alert
  • Field Calibration
  • Infrared Data Download
  • Programmable Auto Shut Off

Applications

  • Ambient Air Safety Checks
  • Fire Service Overhaul Operations

Easy to get started

  1. Press Power
  2. Wait 45 Seconds for Automatic Zeroing
  3. Begin to Use
View the Quick Start Guide for More Details

HCN Effects on Humans
HCN can cause rapid death due to metabolic asphyxiation. Death can occur within minutes or seconds when Hydrogen Cyanide gas is inhaled in high concentrations.

HCN effects on humans

SENSIT 913-00000-11 Specifications

Hydrogen Cyanide (HCN)
Resolution 1ppm
Range 0 to 100ppm
Accuracy ±2ppm or 3% (whichever is greater)
General Specifications
Dimensions 3 x 10 x 2.4" (7.6 x 25.4 x 6cm)
Weight 1.1lbs (0.5kg)
Operational Temperature -4 to 104°F (-20 to 40°C
Battery Life Alkaline: Approximately 30hrs continuous
Click here for complete specifications on the SENSIT HCN

What's included with the SENSIT 913-00000-11

  • Hydrogen Cyanide Gas Analyzer
  • Hard Carrying Case
  • 3 x "C" Batteries
  • Hot Air Probe
  • 5 Foot Flexible Tubing
  • Particle Filter
  • Instruction Manual

Click on a category to view a selection of compatible accessories with the SENSIT 913-00000-11 Hydrogen Cyanide Gas Analyzer, 100ppm HCN.

SENSIT 750-00015 Instruction Manual, HCN 750-00015
This manual will give you further details and instruction on the toxic gas analyzer.




SENSIT 872-00001 Hard Carrying Case for SENSIT Meters 872-00001
This hard plastic carrying case is for use with the SENSIT Gold G2, HXG-3, CO, and HCN. Features dimensions of 5-1/2 x 10 x 13" (13.97 x 25.4 x 33.02cm).




SENSIT 873-00003 Moisture Filter Tube for SENSIT Meters 873-00003
Blue Drierite Desiccant. For use with the SENSIT Gold G2, CO, HCN, and Trak-It IIIa.




SENSIT 873-00005 Dirt and Water Filter Assembly for the CO & HCN 873-00005
For use with the SENSIT CO Combustible Carbon Monoxide Analyzer and HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 873-00017 External Hydrophobic Filter 873-00017
For use with the SENSIT CO Combustible Carbon Monoxide Analyzer and HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 873-00008 Calibration Cartridge for SENSIT Dirt and Water Filters 873-00008
For use with SENSIT Dirt and Water Filter Assemblies, for the Gold G2, CO, HCN, and Trak-It IIIa.




SENSIT 880-00006 Gas Regulator with Adapter Assembly for SENSIT Meters, 0.5Lpm 880-00006
Features a flow rate of 0.5Lpm. The Constant Flow Valve is made out of Stainless Steel. For use with the SENSIT Gold G2, HXG-3, P400, HCN, and Trak-It IIIa.




SENSIT 880-00044 Calibration Adapter for SENSIT Meters 880-00044
For use with the SENSIT Gold G2, HXG-3, P400, HCN, and Trak-It IIIa. Compatible with CH4, CO, H2S, and HCN gasses. Includes a Luer and Tubing.




SENSIT 880-00060 Calibration Gas Regulator for 34, 58, 103, 116L Cylinders 880-00060
For use with the SENSIT Gold G2, HXG-3, P400, CO, HCN, and Trak-It IIIa.




SENSIT 881-00057 Calibration Gas Kit for the HCN, 10ppm HCN, 34L 881-00057
Includes a 34L cylinder of 10ppm Hydrogen Cyanide in Nitrogen gas, a regulator, and hose. For use with the SENSIT HCN Hydrogen Cyanide Gas Analyzer




SENSIT 881-00058 Calibration Kit for the HCN with 2 Cylinders, 100ppm CO and HCN, 34L 881-00058
Includes a 34L cylinder of 10ppm of Carbon Monoxide, a 34L cylinder of Hydrogen Cyanide in Nitrogen gas, a regulator, and hose. For use with the SENSIT HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 883-00023 Hot Air Probe for SENSIT Meters, 47-7/8" 883-00023
This hot air probe is for use with the SENSIT Gold G2, CO, and HCN. Features a diameter of 1-5/8" (4.12cm) and a length of 47-7/8" (121.602cm). Includes hose assembly.




SENSIT 871-00006 Battery Charger with Batteries for SENSIT Meters 871-00006
For use with the SENSIT HXG-3, CO, and HCN.




SENSIT 870-00040 SmartLink Software for SENSIT Meters 870-00040
Does not include IR Link. For use with the SENSIT Gold G2, HXG-3, P400, CO, HCN, and Trak-It IIIa. Works with Windows XP, Windows Vista, and Windows 7.




SENSIT 870-00004 Infrared Printer for SENSIT Meters 870-00004
Features a wireless infrared interface to print saved data for the SENSIT Gold G2, HXG-3, CO, HCN, and Trak-It IIIa.




SENSIT 870-00005 Printer Paper for the 870-00004, Pack of 6 870-00005
Pack of 6 rolls of printer paper, for use with the SENSIT 870-00004 Infrared Printer.




SENSIT 870-00006 Printer Paper for the 870-00004, Single 870-00006
Single pack of printer paper, for use with the SENSIT 870-00004 Infrared Printer.




SENSIT 870-00038 SmartLink IR Link for SENSIT Meters 870-00038
Does not include SmartLink Software. For use with the SENSIT Gold G2, HXG-3, CO, HCN, and Trak-It IIIa.




SENSIT 870-00039 SmartLink IR Link and Software for SENSIT Meters 870-00039
For use with the SENSIT Gold G2, HXG-3, CO, HCN, and Trak-It IIIa. Includes Software, Cable, IR Link, and Installation Guide. Works with Windows XP, Windows Vista, and Windows 7.




SENSIT 315-100001 Calibration Gas for the P100 & HCN, 100ppm CO, 34L 315-100001
Calibration gas mixture of 100ppm Carbon Monoxide in Air. Cylinder has a 34L capacity, and is made of aluminum. Cylinder has a maximum pressure of 985psi and an accuracy of ±10%. Cylinder has a C-10 connection. For use with the SENSIT P100 Single Gas Personal Monitor and HCN Hydrogen Cyanide Gas Analyzer.




SENSIT 315-100006 Calibration Gas, 10ppm HCN, 34L 315-100006
Calibration gas mixture of 10ppm Hydrogen Cyanide in Nitrogen. Cylinder has a 34L capacity, and is made of aluminum. Cylinder has a maximum pressure of 985psi and an accuracy of ±10%. Cylinder has a 5/8"-18 UNF Threaded Collar connection. For use with the SENSIT Gold G2, P100, P400, HCN, and Trak-It IIIa.




Ask a question about SENSIT 913-00000-11 Hydrogen Cyanide Gas Analyzer, 100ppm HCN

Customer Reviews for the SENSIT HCN

More SENSIT Products

Calibration Lab