Testo 0555 6454 Compressed Air Flow Transmitter, 2" Line

Model: 0555 6454 | UPC: 4029547012310

Testo 0555 6454 Compressed Air Flow Transmitter, 2" Line

Model: 0555 6454 | UPC: 4029547012310

Probe sensor is positioned inside of the pipe so its exact coordinates are always known and stay constant. For 2" diameter pipes.

Probe sensor is positioned inside of the pipe so its exact coordinates are always known and stay constant. For 2" diameter pipes.

Sale Price $1284.35 USD
Regular Price $1511.00 USD
Availability 4 to 5 Weeks
Quantity

Testo 0555 6454 Offers

Features

  • Compact design coupled with integrated high-performance technology
  • Offers robustness at the same time as fastest reaction times
  • Superior design from the sensor to the housing
  • Glass-coated ceramic sensor
  • Provides all necessary signal outputs
  • Built-in inflow and outflow pipes allow optimum accuracy
  • Measuring range (1:300): 2,3 to 700 Nm 3 /h
  • Display: 840 Nm 3 /h
  • Measuring stretch: Thread (both sides)/material: R2
  • Stainless steel 1.4401
  • Length measurement pipe: 475 mm (shortened measurement stretches)

For all important diameters: the compressed air counter transmitter in four diameter sizes, this transmitter offers a compact design coupled with integrated high-performance technology, which provides all necessary signal outputs. The built-in inflow and outflow pipes allow optimum accuracy. The thermal, glass-coated ceramic sensor offers robustness at the same time as fastest reaction times. Superior design from the sensor to the housing in contrast to the penetration probes used by competitors, the sensor in this transmitter has a position in the pipe which is exactly known and always the same. With penetration probes, a tilt out of the vertical of 5° already leads to a measurement inaccuracy of 5%. In this transmitter, not only are the inflow and outflow pipes integrated, they also have completely even surfaces (i.e. no flange recesses etc.) Many clever details in the design of this transmitter ensure that the flow profile remains constant and that an optimum of accuracy can be achieved.Defined interior diameter and volume flow adjustment for highest accuracy especially in small diameters, the exact knowledge of the interior diameter plays a deciding part in achieving accurate measurements of norm volume flow. Commercially available penetration probes measure the flow velocity and calculate the volume flow by multiplication with the cross-section area. As shown in the illustration, even normed pipes can vary in interior diameter to such a degree that inaccuracies of up to 33% are possible. This transmitter has an exactly known diameter – and is adjusted directly according to norm volume flow, and not flow velocity!

Testo 0555 6454 Specifications

Measurement Parameters
(Normal) Volume Flow Selectable units: m3/h; l/min; m3
Measuring range (1:300)*: 2.3 to 700 m3/h
Accuracy (normal volume flow): For compressed air quality classes (ISO 8573: particles-humidity-oil) 1-4-1: ±3% of measurement value ±0.3% of final value
For compressed air quality classes (ISO 8573: particles-humidity-oil) 3-4-4: ±6% of measurement value ±0.6% of final value
Sensor: Thermal, glass-coated ceramic sensor (calorimetric measurement procedure)
Response time: <0.1 seconds (for damping parameter = 0), delayable via operating menu (0 to 1 second)
*1) Specifications according to DIN 2533 (15°C, 1013.25 hPa, 0% RH)
Temperature Unit: °C
Measuring range: 32 to 140°F/0 to 60°C
Inputs and Outputs
Analog Output Output type: 4 to 20 mA (4-wire) freely scalable between zero and measuring range end
Load: maximum 500 Ω
Further Outputs Pulse output: Consumption quantity counter (value remains available after reset or power cut due to non-volatile memory), value 1 or 10 m3, pulse length 0.02 to 2 s, 24 V DC level
Switch output: 2 switch outputs, parameterizable (consumption or volume flow-dependent, opener, closer, hysteresis, window), loadable with maximum 20 to 30 V DC or 250 mA each, switch status is displayed via 2 LEDs
Supply Voltage supply: 19 to 30 V DC
Current consumption: <100 mA
Connection: M12 x 1 plug, loadable up to 250 mA, short-circuit-proof (synchronized), reverse-polarity-proof, overload-proof
General Specifications
Display Material: 4-figure alphanumerical display, two operating buttons, operating menu, LED (4 x green for physical units, 3 x yellow for display x 1000 or switch status)
Maximum display value normal volume flow: 840 m3/h
Temperature display: 32 to 140°F, measurement error ±2 K, (0 to 60°C)
Operation Parameterization: 2 operating buttons
Installation Measurement stretch: thread (both sides)/material: R2, outer thread stainless steel 1.4401
Humidity (Sensor) Relative humidity <90% RH
Temperature Opreating (housing): 32 to 140°F (0 to 60°C)
Storage: -13 to 185°F (-25 to 85°C)
Measurement Medium Compressed air
Process Pressure PN 16 (maximum 16 bar/232psi)
Air Quality ISO 8573: recommended classes 1-4-1
Material Housing PBT (GF 20%), diecast zinc, silica-free
Protection Class IP 65/III
EMC According to guideline 89/336 EEC
Media Contact Materials stainless or galvanized steel, PEEK, polyester, Viton, anodized aluminium ceramic
Long Measurement Stretch 475 mm
Pipe Diameter DN 50 (for 2" pipes)
Weight 8.38 lbs (3.8 kg)
Click here for complete specifications on the Testo 0555 6454

What's included with the Testo 0555 6454

  • Testo 0555 6454 Compressed Air Flow Transmitter, 2" Line

Ask a question about Testo 0555 6454 Compressed Air Flow Transmitter, 2" Line

Customer Reviews for the Testo 0555 6454

Testo 0555 6454 Offers

Features

  • Compact design coupled with integrated high-performance technology
  • Offers robustness at the same time as fastest reaction times
  • Superior design from the sensor to the housing
  • Glass-coated ceramic sensor
  • Provides all necessary signal outputs
  • Built-in inflow and outflow pipes allow optimum accuracy
  • Measuring range (1:300): 2,3 to 700 Nm 3 /h
  • Display: 840 Nm 3 /h
  • Measuring stretch: Thread (both sides)/material: R2
  • Stainless steel 1.4401
  • Length measurement pipe: 475 mm (shortened measurement stretches)

For all important diameters: the compressed air counter transmitter in four diameter sizes, this transmitter offers a compact design coupled with integrated high-performance technology, which provides all necessary signal outputs. The built-in inflow and outflow pipes allow optimum accuracy. The thermal, glass-coated ceramic sensor offers robustness at the same time as fastest reaction times. Superior design from the sensor to the housing in contrast to the penetration probes used by competitors, the sensor in this transmitter has a position in the pipe which is exactly known and always the same. With penetration probes, a tilt out of the vertical of 5° already leads to a measurement inaccuracy of 5%. In this transmitter, not only are the inflow and outflow pipes integrated, they also have completely even surfaces (i.e. no flange recesses etc.) Many clever details in the design of this transmitter ensure that the flow profile remains constant and that an optimum of accuracy can be achieved.Defined interior diameter and volume flow adjustment for highest accuracy especially in small diameters, the exact knowledge of the interior diameter plays a deciding part in achieving accurate measurements of norm volume flow. Commercially available penetration probes measure the flow velocity and calculate the volume flow by multiplication with the cross-section area. As shown in the illustration, even normed pipes can vary in interior diameter to such a degree that inaccuracies of up to 33% are possible. This transmitter has an exactly known diameter – and is adjusted directly according to norm volume flow, and not flow velocity!

Testo 0555 6454 Specifications

Measurement Parameters
(Normal) Volume Flow Selectable units: m3/h; l/min; m3
Measuring range (1:300)*: 2.3 to 700 m3/h
Accuracy (normal volume flow): For compressed air quality classes (ISO 8573: particles-humidity-oil) 1-4-1: ±3% of measurement value ±0.3% of final value
For compressed air quality classes (ISO 8573: particles-humidity-oil) 3-4-4: ±6% of measurement value ±0.6% of final value
Sensor: Thermal, glass-coated ceramic sensor (calorimetric measurement procedure)
Response time: <0.1 seconds (for damping parameter = 0), delayable via operating menu (0 to 1 second)
*1) Specifications according to DIN 2533 (15°C, 1013.25 hPa, 0% RH)
Temperature Unit: °C
Measuring range: 32 to 140°F/0 to 60°C
Inputs and Outputs
Analog Output Output type: 4 to 20 mA (4-wire) freely scalable between zero and measuring range end
Load: maximum 500 Ω
Further Outputs Pulse output: Consumption quantity counter (value remains available after reset or power cut due to non-volatile memory), value 1 or 10 m3, pulse length 0.02 to 2 s, 24 V DC level
Switch output: 2 switch outputs, parameterizable (consumption or volume flow-dependent, opener, closer, hysteresis, window), loadable with maximum 20 to 30 V DC or 250 mA each, switch status is displayed via 2 LEDs
Supply Voltage supply: 19 to 30 V DC
Current consumption: <100 mA
Connection: M12 x 1 plug, loadable up to 250 mA, short-circuit-proof (synchronized), reverse-polarity-proof, overload-proof
General Specifications
Display Material: 4-figure alphanumerical display, two operating buttons, operating menu, LED (4 x green for physical units, 3 x yellow for display x 1000 or switch status)
Maximum display value normal volume flow: 840 m3/h
Temperature display: 32 to 140°F, measurement error ±2 K, (0 to 60°C)
Operation Parameterization: 2 operating buttons
Installation Measurement stretch: thread (both sides)/material: R2, outer thread stainless steel 1.4401
Humidity (Sensor) Relative humidity <90% RH
Temperature Opreating (housing): 32 to 140°F (0 to 60°C)
Storage: -13 to 185°F (-25 to 85°C)
Measurement Medium Compressed air
Process Pressure PN 16 (maximum 16 bar/232psi)
Air Quality ISO 8573: recommended classes 1-4-1
Material Housing PBT (GF 20%), diecast zinc, silica-free
Protection Class IP 65/III
EMC According to guideline 89/336 EEC
Media Contact Materials stainless or galvanized steel, PEEK, polyester, Viton, anodized aluminium ceramic
Long Measurement Stretch 475 mm
Pipe Diameter DN 50 (for 2" pipes)
Weight 8.38 lbs (3.8 kg)
Click here for complete specifications on the Testo 0555 6454

What's included with the Testo 0555 6454

  • Testo 0555 6454 Compressed Air Flow Transmitter, 2" Line

Ask a question about Testo 0555 6454 Compressed Air Flow Transmitter, 2" Line