Built to keep you safe, this advanced wire tracer kit accurately and safely troubleshoots energized/de-energized wires in residential, commercial, and industrial environments up to CAT IV 600 V. In addition, this wire tracing kit comes with a receiver, a transmitter, an AC current clamp, a test lead kit, and a carrying case.
Built to keep you safe, this advanced wire tracer kit accurately and safely troubleshoots energized/de-energized wires in residential, commercial, and industrial environments up to CAT IV 600 V. In addition, this wire tracing kit comes with a receiver, a transmitter, an AC current clamp, a test lead kit, and a carrying case.
Fast, easy, and safe troubleshooting, this advanced wire tracer kit features a CAT IV 600 V rating, offering the highest protection on any wire tracer. Spikes up to 8000 V can occur in industrial and utility environments, which is where this kit excels at protecting you from these dangerous levels of transient overvoltage. This protection is crucial for scenarios in environments like industrial plants, factories, and hospitals where critical equipment cannot be offline.
Features
Wire tracing customized for your application
Whether troubleshooting electrical wiring and equipment in residential homes, commercial buildings, or high-voltage utility plants, this advanced wire tracer kit can find breaks or opens and shorts. Its different modes and functions give you the flexibility to troubleshoot a wide range of electrical wiring and circuitry problems you may encounter on the job.
Four receiver tracing modes
The included receiver detects the signal in wires and cables using two methods: passive tracing without the transmitter for non-contact voltage detection and active tracing with the transmitter for all other modes. The receiver's tip sensor can trace wires in corners, tight spaces, and junction boxes.
Three transmitter power modes
The included transmitter works on energized and de-energized circuits up to CAT IV 600 V and features high, low, and loop modes. These modes change the strength of the induced signal and can help provide more accurate results, depending on the circuit you're tracing.
Applications
Receiver | |
Measurement Category | CAT IV 600 V |
Operating Voltage/Frequency | Voltage: 600 V AC/DC Frequency: Energized: 6.25 kHz De-energized: 32.768 kHz |
Signal Indications | Numeric, bar graph display, and audible beep |
Response Time | Tip sensor (energized/de-energized): 500 ms NCV: 500 ms Battery monitoring: 5 seconds |
Range Detection (open air) | Tip sensor: Energized Maximum distance via air: Up to 20' (6.1 m) Pinpointing: Approximately 1.97" (5 cm) Tip sensor: De-energized Maximum distance via air: Up to 14.7' (4.5 m) Pinpointing: Approximately 1.97" (5 cm) NCV (40 to 400 Hz) Maximum sensitivity: 90 V up to 6.6' (2 m) Minimum sensitivity: 600 V up to 0.4" (1 cm) |
Display | Size: LCD 2.5" (63 mm) Dimensions: 1.45 x 1.93" (37 x 49 mm) Resolution: 240 x 320 Type: TFT LCD Color: 16-bit Backlight: Yes |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) Operating humidity: 45%: -4 to <50°F or 104 to 122°F (-20 to <10°C or 40 to 50°C) 95% (non-condensing): 50 to 86°F (10 to <30°C) 75%: 86 to <104°F (30 to <40°C) Operating altitude: 6261' (2000 m) Pollution degree: 2 IP rating: IP40 Drop test: 3.28' (1 m) |
Power | Type: 4 x AA (alkaline) Consumption (typical): 110 mA Battery life: Approximately 16 hours Low battery indicator: Yes |
Dimensions | Approximately 7.2 x 2.95 x 1.69" (183 x 75 x 43 mm) |
Weight | Approximately 0.6 lbs (0.27 kg) |
Transmitter | |
Measurement Category | CAT IV 600 V |
Operating Voltage/Frequency | Voltage: 600 V AC/DC Frequency: Energized/Loop: 6.25 kHz De-energized: 32.768 kHz |
Signal Indications | LEDs and audible beep |
Response Time | Line voltage monitoring: 1 second Battery voltage monitoring: 5 seconds |
Current Output of Signal (typical) | Energized circuit: High mode: 60 mA rms Low mode: 30 mA rms De-energized circuit: High mode: 110 mA rms Low mode: 40 mA rms Loop mode with test leads: 160 mA rms Loop mode with AC current clamp: 385 mA rms |
Signal Voltage Output (nominal) | Energized circuit: High mode: 14 W at 230 V AC/50 Hz, 3.33 kΩ at 230 V AC Low mode: 4.6 W at 230 V AC/50 Hz, 11.5 kΩ at 230 V AC De-energized circuit: High mode: 31 Vrms, 140 Vp-p, 0.86 W at 1 kΩ load Low mode: 27.5 Vrms, 120 Vp-p, 0.1 W at 1 kΩ load Loop mode with test leads: 32 Vrms, 140 Vp-p, 0.87 W at 1 kΩ load Loop mode with AC current clamp: 31 mV, 0.89 W at 1 Ω load |
Display | Size: LEDs Type: LEDs Color: Operating mode LEDs: Red Battery status LEDs: Green, yellow, red |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) Operating humidity: 45%: -4 to <50°F or 104 to 122°F (-20 to <10°C or 40 to 50°C) 95% (non-condensing): 50 to 86°F (10 to <30°C) 75%: 86 to <104°F (30 to <40°C) Operating altitude: 6261' (2000 m) Transient protection: 8 kV (1.2/50 µS surge) Pollution degree: 2 IP rating: IP40 Drop test: 3.28' (1 m) |
Power | Type: 8 x AA (alkaline) Consumption (typical): High/low mode: 70 mA Loop mode with clamp: 90 mA Consumption without signal transmission: 10 mA Battery life: High/low mode: Approximately 25 hours Loop mode: Approximately 18 hours Fuse: 1.6 A, 700 V, fast-acting, Ø0.2 x 1.3" (Ø6 x 32 mm), 50 kA interrupt Low battery indicator: Yes |
Dimensions | Approximately 7.2 x 3.66 x 1.97" (183 x 93 x 50 mm) |
Weight | Approximately 1.25 lbs (0.57 kg) |
Accurate and flexible, this receiver detects signals in wires and cables using passive tracing without the transmitter for non-contact voltage detection and active tracing with the transmitter for all other modes. In addition, it features four tracing modes, and the tip sensor traces wires in corners, tight spaces, and junction boxes.
Works on energized and de-energized circuits up to CAT IV 600 V, this transmitter automatically senses whether the system is energized or de-energized and selects a 6 or 33 kHz output frequency. In addition, it features high, low, and loop modes, changing the strength of the induced signal and providing more accurate results.
Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.
Compatible with the 2052 advanced wire tracer and 2062 advanced pro wire tracer, this test lead kit conveniently includes everything required to start tracing wires and circuits. In addition, this kit comes with a mix of outlet adapters and alligator clips for versatility when connecting test leads to circuits and wires.
Click on a category to view a selection of compatible accessories with the Fluke 2052 Advanced Wire Tracer Kit, CAT IV 600 V, 600 V AC/DC.
Receiver | |
Measurement Category | CAT IV 600 V |
Operating Voltage/Frequency | Voltage: 600 V AC/DC Frequency: Energized: 6.25 kHz De-energized: 32.768 kHz |
Signal Indications | Numeric, bar graph display, and audible beep |
Response Time | Tip sensor (energized/de-energized): 500 ms NCV: 500 ms Battery monitoring: 5 seconds |
Range Detection (open air) | Tip sensor: Energized Maximum distance via air: Up to 20' (6.1 m) Pinpointing: Approximately 1.97" (5 cm) Tip sensor: De-energized Maximum distance via air: Up to 14.7' (4.5 m) Pinpointing: Approximately 1.97" (5 cm) NCV (40 to 400 Hz) Maximum sensitivity: 90 V up to 6.6' (2 m) Minimum sensitivity: 600 V up to 0.4" (1 cm) |
Display | Size: LCD 2.5" (63 mm) Dimensions: 1.45 x 1.93" (37 x 49 mm) Resolution: 240 x 320 Type: TFT LCD Color: 16-bit Backlight: Yes |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) Operating humidity: 45%: -4 to <50°F or 104 to 122°F (-20 to <10°C or 40 to 50°C) 95% (non-condensing): 50 to 86°F (10 to <30°C) 75%: 86 to <104°F (30 to <40°C) Operating altitude: 6261' (2000 m) Pollution degree: 2 IP rating: IP40 Drop test: 3.28' (1 m) |
Power | Type: 4 x AA (alkaline) Consumption (typical): 110 mA Battery life: Approximately 16 hours Low battery indicator: Yes |
Dimensions | Approximately 7.2 x 2.95 x 1.69" (183 x 75 x 43 mm) |
Weight | Approximately 0.6 lbs (0.27 kg) |
Transmitter | |
Measurement Category | CAT IV 600 V |
Operating Voltage/Frequency | Voltage: 600 V AC/DC Frequency: Energized/Loop: 6.25 kHz De-energized: 32.768 kHz |
Signal Indications | LEDs and audible beep |
Response Time | Line voltage monitoring: 1 second Battery voltage monitoring: 5 seconds |
Current Output of Signal (typical) | Energized circuit: High mode: 60 mA rms Low mode: 30 mA rms De-energized circuit: High mode: 110 mA rms Low mode: 40 mA rms Loop mode with test leads: 160 mA rms Loop mode with AC current clamp: 385 mA rms |
Signal Voltage Output (nominal) | Energized circuit: High mode: 14 W at 230 V AC/50 Hz, 3.33 kΩ at 230 V AC Low mode: 4.6 W at 230 V AC/50 Hz, 11.5 kΩ at 230 V AC De-energized circuit: High mode: 31 Vrms, 140 Vp-p, 0.86 W at 1 kΩ load Low mode: 27.5 Vrms, 120 Vp-p, 0.1 W at 1 kΩ load Loop mode with test leads: 32 Vrms, 140 Vp-p, 0.87 W at 1 kΩ load Loop mode with AC current clamp: 31 mV, 0.89 W at 1 Ω load |
Display | Size: LEDs Type: LEDs Color: Operating mode LEDs: Red Battery status LEDs: Green, yellow, red |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) Operating humidity: 45%: -4 to <50°F or 104 to 122°F (-20 to <10°C or 40 to 50°C) 95% (non-condensing): 50 to 86°F (10 to <30°C) 75%: 86 to <104°F (30 to <40°C) Operating altitude: 6261' (2000 m) Transient protection: 8 kV (1.2/50 µS surge) Pollution degree: 2 IP rating: IP40 Drop test: 3.28' (1 m) |
Power | Type: 8 x AA (alkaline) Consumption (typical): High/low mode: 70 mA Loop mode with clamp: 90 mA Consumption without signal transmission: 10 mA Battery life: High/low mode: Approximately 25 hours Loop mode: Approximately 18 hours Fuse: 1.6 A, 700 V, fast-acting, Ø0.2 x 1.3" (Ø6 x 32 mm), 50 kA interrupt Low battery indicator: Yes |
Dimensions | Approximately 7.2 x 3.66 x 1.97" (183 x 93 x 50 mm) |
Weight | Approximately 1.25 lbs (0.57 kg) |
Accurate and flexible, this receiver detects signals in wires and cables using passive tracing without the transmitter for non-contact voltage detection and active tracing with the transmitter for all other modes. In addition, it features four tracing modes, and the tip sensor traces wires in corners, tight spaces, and junction boxes.
Works on energized and de-energized circuits up to CAT IV 600 V, this transmitter automatically senses whether the system is energized or de-energized and selects a 6 or 33 kHz output frequency. In addition, it features high, low, and loop modes, changing the strength of the induced signal and providing more accurate results.
Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.
Compatible with the 2052 advanced wire tracer and 2062 advanced pro wire tracer, this test lead kit conveniently includes everything required to start tracing wires and circuits. In addition, this kit comes with a mix of outlet adapters and alligator clips for versatility when connecting test leads to circuits and wires.
Click on a category to view a selection of compatible accessories with the Fluke 2052 Advanced Wire Tracer Kit, CAT IV 600 V, 600 V AC/DC.