An accurate, and reliable environmental meter to help you verify that duct inlets and outlets have the specified volumetric flow _ a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, it can measure deviations from proper relative humidity levels.
An accurate, and reliable environmental meter to help you verify that duct inlets and outlets have the specified volumetric flow _ a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, it can measure deviations from proper relative humidity levels.
Designed for HVAC/R professionals who need an accurate, and reliable environmental meter. The included contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures. All it takes is one tool to get all the environmental and equipment temperature measurements you need.
Accurate and Reliable
Rely on this affordable meter to provide accurate, high-quality data consistently, and complete your work without interruption.
Inspect and Troubleshoot Efficiently
Execute your work on a wide range of systems more efficiently.
Easy to Use
Intuitively operate this simple, ergonomic meter.
Applications
Environmental Measurements | |
Air Velocity (Vane Anemometer Probe) | Range: 0.4 to 30 m/s, 79 to 5906 ft/min, 1.4 to 108.0 km/h, 0.9 to 67.2 mph, 0.8 to 58.3 knots Accuracy: ±3% +0.2 m/s, ±3% +40 ft/min, ±3% +0.8 km/h, ±3% +0.4 mph, ±3% +0.4 knots |
Air Flow | 0 to 999900 CMM (0 to 999900 CFM) |
Air Temperature | Range: 50 to 86°F (10 to 30°C), -22 to 50°F (-30 to 9.9°C) and 88 to 140°F (31 to 60°C) Accuracy: ±1.8°F (1°C), ±3.6°F (2°C) |
Air Relative Humidity | Range: 5 to 98% Accuracy: ±3.5% |
Dew Point (Calculated) | Range: -22 to 140°F (-30 to 60°C) Accuracy: ±4.8°F (3°C) |
Wet Bulb (Calculated) | Range: -22 to 122°F (-30 to 50°C) Accuracy: ±4.8°F (3°C) |
Contact Temperature (Type K Thermocouple) | Range: 212 to 2502°F (100 to 1372°C) Accuracy: ±1.5% +3.6°F (2°C) |
General Specifications | |
Display | Backlit, multifunction LCD |
Battery | Type: 1 x 9 V battery Life: 120 hours typical Status indicator: Low battery indication |
Auto Power Off (APO) | Configurable from 5 to 60 min in 8 increments |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | 14 to 140°F (-10 to 60°C) |
Certifications | CE, RCM |
Dimensions | 10.8 x 2.6 x 1.8" (275 x 65 x 45 mm) |
Weight | 10 oz (283.9 g) with battery installed, no external probes |
Environmental Measurements | |
Air Velocity (Vane Anemometer Probe) | Range: 0.4 to 30 m/s, 79 to 5906 ft/min, 1.4 to 108.0 km/h, 0.9 to 67.2 mph, 0.8 to 58.3 knots Accuracy: ±3% +0.2 m/s, ±3% +40 ft/min, ±3% +0.8 km/h, ±3% +0.4 mph, ±3% +0.4 knots |
Air Flow | 0 to 999900 CMM (0 to 999900 CFM) |
Air Temperature | Range: 50 to 86°F (10 to 30°C), -22 to 50°F (-30 to 9.9°C) and 88 to 140°F (31 to 60°C) Accuracy: ±1.8°F (1°C), ±3.6°F (2°C) |
Air Relative Humidity | Range: 5 to 98% Accuracy: ±3.5% |
Dew Point (Calculated) | Range: -22 to 140°F (-30 to 60°C) Accuracy: ±4.8°F (3°C) |
Wet Bulb (Calculated) | Range: -22 to 122°F (-30 to 50°C) Accuracy: ±4.8°F (3°C) |
Contact Temperature (Type K Thermocouple) | Range: 212 to 2502°F (100 to 1372°C) Accuracy: ±1.5% +3.6°F (2°C) |
General Specifications | |
Display | Backlit, multifunction LCD |
Battery | Type: 1 x 9 V battery Life: 120 hours typical Status indicator: Low battery indication |
Auto Power Off (APO) | Configurable from 5 to 60 min in 8 increments |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | 14 to 140°F (-10 to 60°C) |
Certifications | CE, RCM |
Dimensions | 10.8 x 2.6 x 1.8" (275 x 65 x 45 mm) |
Weight | 10 oz (283.9 g) with battery installed, no external probes |