Practical tool for any leak detection, steam trap inspection or mechanical troubleshooting program. Ultrasound instruments can be used in noisy environments.
Practical tool for any leak detection, steam trap inspection or mechanical troubleshooting program. Ultrasound instruments can be used in noisy environments.
Features
Circuitry | SMD/Solid state hybrid heterodyne receiver |
Frequency Response | 20-100 kHz (centered @ 38 to 42 kHz) |
Indicator | 10 segment LED bar graph (red) |
Sensitivity Selection | 8 position precision attenuation |
Headset | Noise isolating type: double headset wired monophonic impedance 16Ω Over 23dB noise attenuation Meets ANSI specifications & OSHA standards |
Probes | Scanning Module (SCM-1): Stainless steel unisonic (single transducer) piezo electric crystal type Stethoscope/Contact Module (STM-1): Stainless steel plug-in type with 5.5" stainless steel wave — guide Rubber Focusing Probe: Shields stray ultrasonic signals & focuses detected signal |
Transmitter | Patented warble tone transmission |
Response Time | 300 m sec |
Power Supply | 9 V alkaline battery |
Dimensions | 5.25 x 2 x 8" (133 x 50 x 203 mm) |
Weight | 11 oz (0.3 kg) |
Circuitry | SMD/Solid state hybrid heterodyne receiver |
Frequency Response | 20-100 kHz (centered @ 38 to 42 kHz) |
Indicator | 10 segment LED bar graph (red) |
Sensitivity Selection | 8 position precision attenuation |
Headset | Noise isolating type: double headset wired monophonic impedance 16Ω Over 23dB noise attenuation Meets ANSI specifications & OSHA standards |
Probes | Scanning Module (SCM-1): Stainless steel unisonic (single transducer) piezo electric crystal type Stethoscope/Contact Module (STM-1): Stainless steel plug-in type with 5.5" stainless steel wave — guide Rubber Focusing Probe: Shields stray ultrasonic signals & focuses detected signal |
Transmitter | Patented warble tone transmission |
Response Time | 300 m sec |
Power Supply | 9 V alkaline battery |
Dimensions | 5.25 x 2 x 8" (133 x 50 x 203 mm) |
Weight | 11 oz (0.3 kg) |