TSI EBT731-STA Balometer Capture Hood with stand and tablet

Model: EBT731-STA

TSI EBT731-STA Balometer Capture Hood with stand and tablet

Model: EBT731-STA

Ergonomic and lightweight, this multipurpose electronic air balancing instrument is ideal for taking accurate, direct air volume measurements at diffusers and grilles. This bundle includes a capture hood, a capture hood stand, and a smart tablet loaded with LogDat™ software and instruction videos.

Ergonomic and lightweight, this multipurpose electronic air balancing instrument is ideal for taking accurate, direct air volume measurements at diffusers and grilles. This bundle includes a capture hood, a capture hood stand, and a smart tablet loaded with LogDat™ software and instruction videos.

This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.

Sale Price $3744.00 USD
Regular Price $4160.00 USD
Availability 12 to 13 Weeks
Quantity

TSI/Alnor EBT731-STA Offers

Offering durable, trouble-free operation, this lightweight, ergonomically designed capture hood kit saves time and money by combining multiple measurement tools into one package. The balometer capture hood helps you create healthy and energy efficient environments while meeting local codes, guidelines and regulations for ventilation systems.

The capture hood features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.

Features

  • Ergonomic, lightweight design enables easy one-person operation
  • Automatic sensing and display of supply or return flows saves time on the job
  • Back pressure compensation ensures accurate readings at high flow rates
  • Detachable digital micromanometer provides additional measurement capability
  • Multiple hood size options enable measurement of different outlet dimensions
  • Compatible LogDat Mobile Remote Reader and Data Logger Software simplifies documenting of results and emailing of reports
  • Capture hood stand eliminates the need for ladders (reaching diffusers up to 15')

Applications

  • Test and balance contractors
  • Commissioning agents
  • Facilities managers
  • Health and safety specialists
  • Ventilation system installers

TSI/Alnor EBT731-STA Specifications

Velocity Range
Pitot Probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity Matrix 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 inH2O (±3735 Pa)
150 inH2O (37.5 kPa)
Maximum safe operating pressure
Absolute Pressure 15 to 40 inHg (356 to 1016 mmHg)
Accuracy ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential
±2% of reading absolute
Resolution 0.00001 inH2O (0.001 Pa) static and differential
0.01 inHg (1 mmHg) absolute
General Specifications
Instrument Temperature Range Operating: 40 to 140°F (4.4 to 60°C)
Storage: -4 to 160°F (-20 to 71°C)
Weight 7.4 lbs (3.4 kg)
Click here for complete specifications on the TSI/Alnor EBT731-STA

What's included with the TSI/Alnor EBT731-STA

  • Capture Hood
  • NIST-Traceable Calibration Certificate
  • Capture Hood Stand
  • Tablet with LogDat™ Software and Instruction Videos
  • Air Capture Hood/Frame/Base, 2 x 2' (61 x 61 cm)
  • Detachable Micromanometer
  • Multi-Country AC Adapter
  • Pitot Probe, 18" (46 cm)
  • 2 x Static Pressure Probes
  • Neoprene Tubing, 16' (4.8 m)
  • USB Interface Cable
  • Downloading Software
  • Wheeled Luggage-Style Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • Product Manual

Click on a category to view a selection of compatible accessories with the TSI EBT731-STA Balometer Capture Hood with stand and tablet.

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-60 Stainless Steel Pitot Tube (5/16" dia. X 60"L) 160-60
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-36 Stainless Steel Pitot Tube (5/16" dia. X 36"L) 160-36
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-24 Stainless Steel Pitot Tube (5/16" dia. X 24"L) 160-24
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-18 Stainless Steel Pitot Tube (5/16" dia. X 18"L) 160-18
No calibration needed. Precisely located, burr-free static pressure holes.








TSI/Alnor 801207 Hood Expansion Kit for the EBT731, 1 x 5' and 3 x 3' 801207
For use with the EBT731 Balometer Capture Hood.




TSI/Alnor 801090 16 Point Velocity Matrix Add On Kit with Telescopic Handle 801090
Grid covers 1 ft2 (0.09 m2) and averages the air velocity while minimizing the effects of turbulence to produce a stable reading.




TSI/Alnor 800187 Air Flow Probe, 18" 800187
For use with the EBT731.




Ask a question about TSI EBT731-STA Balometer Capture Hood with stand and tablet

Customer Reviews for the TSI/Alnor EBT731-STA

TSI/Alnor EBT731-STA Offers

Offering durable, trouble-free operation, this lightweight, ergonomically designed capture hood kit saves time and money by combining multiple measurement tools into one package. The balometer capture hood helps you create healthy and energy efficient environments while meeting local codes, guidelines and regulations for ventilation systems.

The capture hood features a detachable micromanometer which can be used with optional probes for increased flexibility in multiple measurement applications.

Features

  • Ergonomic, lightweight design enables easy one-person operation
  • Automatic sensing and display of supply or return flows saves time on the job
  • Back pressure compensation ensures accurate readings at high flow rates
  • Detachable digital micromanometer provides additional measurement capability
  • Multiple hood size options enable measurement of different outlet dimensions
  • Compatible LogDat Mobile Remote Reader and Data Logger Software simplifies documenting of results and emailing of reports
  • Capture hood stand eliminates the need for ladders (reaching diffusers up to 15')

Applications

  • Test and balance contractors
  • Commissioning agents
  • Facilities managers
  • Health and safety specialists
  • Ventilation system installers

TSI/Alnor EBT731-STA Specifications

Velocity Range
Pitot Probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air Flow Probe 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity Matrix 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential Pressure ±15 inH2O (±3735 Pa)
150 inH2O (37.5 kPa)
Maximum safe operating pressure
Absolute Pressure 15 to 40 inHg (356 to 1016 mmHg)
Accuracy ±2% of reading ±0.0001 inH2O (±0.025 Pa) static and differential
±2% of reading absolute
Resolution 0.00001 inH2O (0.001 Pa) static and differential
0.01 inHg (1 mmHg) absolute
General Specifications
Instrument Temperature Range Operating: 40 to 140°F (4.4 to 60°C)
Storage: -4 to 160°F (-20 to 71°C)
Weight 7.4 lbs (3.4 kg)
Click here for complete specifications on the TSI/Alnor EBT731-STA

What's included with the TSI/Alnor EBT731-STA

  • Capture Hood
  • NIST-Traceable Calibration Certificate
  • Capture Hood Stand
  • Tablet with LogDat™ Software and Instruction Videos
  • Air Capture Hood/Frame/Base, 2 x 2' (61 x 61 cm)
  • Detachable Micromanometer
  • Multi-Country AC Adapter
  • Pitot Probe, 18" (46 cm)
  • 2 x Static Pressure Probes
  • Neoprene Tubing, 16' (4.8 m)
  • USB Interface Cable
  • Downloading Software
  • Wheeled Luggage-Style Carrying Case
  • 4 x AA Rechargeable NiMH Batteries
  • Product Manual

Click on a category to view a selection of compatible accessories with the TSI EBT731-STA Balometer Capture Hood with stand and tablet.

Dwyer 160-12 Stainless Steel Pitot Tube (5/16" dia. X 12"L) 160-12
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-60 Stainless Steel Pitot Tube (5/16" dia. X 60"L) 160-60
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-36 Stainless Steel Pitot Tube (5/16" dia. X 36"L) 160-36
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-24 Stainless Steel Pitot Tube (5/16" dia. X 24"L) 160-24
No calibration needed. Precisely located, burr-free static pressure holes.




Dwyer 160-18 Stainless Steel Pitot Tube (5/16" dia. X 18"L) 160-18
No calibration needed. Precisely located, burr-free static pressure holes.








TSI/Alnor 801207 Hood Expansion Kit for the EBT731, 1 x 5' and 3 x 3' 801207
For use with the EBT731 Balometer Capture Hood.




TSI/Alnor 801090 16 Point Velocity Matrix Add On Kit with Telescopic Handle 801090
Grid covers 1 ft2 (0.09 m2) and averages the air velocity while minimizing the effects of turbulence to produce a stable reading.




TSI/Alnor 800187 Air Flow Probe, 18" 800187
For use with the EBT731.