Used with pitot tubes (sold separately) to measure quickly and accurately measure differential and static pressure and duct velocity, this high-performance handheld micromanometer is easy to operate. In addition, it can calculate flow, has data logging capabilities, and comes with an ISO accreditation for differential pressure.
Used with pitot tubes (sold separately) to measure quickly and accurately measure differential and static pressure and duct velocity, this high-performance handheld micromanometer is easy to operate. In addition, it can calculate flow, has data logging capabilities, and comes with an ISO accreditation for differential pressure.
Features
Applications
Static/Differential Pressure | Range: -15 to 15 "H2O (-28 to 28 mm Hg, -3735 to 3735 Pa) Accuracy: ±1% of reading ±0.0005 "H2O (±0.01 mm Hg, ±1 Pa) Resolution: 0.001 "H2O (0.1 Pa, 0.01 mmHg) |
Velocity (Pitot Tube Required) | Range2: 250 to 15,500 ft/min (1.27 to 78.7 m/s) Accuracy3: ±1.5% at 2000 ft/min (10.16 m/s) Resolution: 1 ft/min (0.1 m/s) |
Duct Size | 1 to 500" in increments of 0.1" (2.5 to 1270 cm in increments of 0.1 cm) |
Volumetric Flow Rate | Actual rate is a function of velocity, pressure, duct size, and K factor |
Data Storage | 12,700 samples and 100 test IDs |
Logging Interval | 1 second to 1 hour |
Time Constant | User selectable |
Environmental Conditions | Operating temperature: 40 to 113°F (5 to 45°C) Storage temperature: -4 to 140°F (-20 to 60°C) |
Power Requirements | 4 x AA batteries or optional AC adapter (sold separately) |
Dimensions | 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm) |
Weight | 0.6 lbs (0.27 kg) |
Click on a category to view a selection of compatible accessories with the TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation.
Static/Differential Pressure | Range: -15 to 15 "H2O (-28 to 28 mm Hg, -3735 to 3735 Pa) Accuracy: ±1% of reading ±0.0005 "H2O (±0.01 mm Hg, ±1 Pa) Resolution: 0.001 "H2O (0.1 Pa, 0.01 mmHg) |
Velocity (Pitot Tube Required) | Range2: 250 to 15,500 ft/min (1.27 to 78.7 m/s) Accuracy3: ±1.5% at 2000 ft/min (10.16 m/s) Resolution: 1 ft/min (0.1 m/s) |
Duct Size | 1 to 500" in increments of 0.1" (2.5 to 1270 cm in increments of 0.1 cm) |
Volumetric Flow Rate | Actual rate is a function of velocity, pressure, duct size, and K factor |
Data Storage | 12,700 samples and 100 test IDs |
Logging Interval | 1 second to 1 hour |
Time Constant | User selectable |
Environmental Conditions | Operating temperature: 40 to 113°F (5 to 45°C) Storage temperature: -4 to 140°F (-20 to 60°C) |
Power Requirements | 4 x AA batteries or optional AC adapter (sold separately) |
Dimensions | 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm) |
Weight | 0.6 lbs (0.27 kg) |
Click on a category to view a selection of compatible accessories with the TSI/Alnor 5825-AC DP-Calc High-Performance Micromanometer with ISO 17025 accreditation.