This model is designed for passenger railroads using 100Hz and 250Hz coding systems. The all pass position bypasses cab filters.
This model is designed for passenger railroads using 100Hz and 250Hz coding systems. The all pass position bypasses cab filters.
The 2000 Series Railroad Testers from Triplett Test Equipment and Tools are specialized Test Sets designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment.
The 2000 Series is compatible with older test technologies, yet is easier to use, and offers test features not found on earlier test sets. Fewer jacks, more ranges, and a logical front panel layout all contribute to the 2000 Series' ease of use. A precision multi-turn Ohms Adjust Control facilitates accurate resistance measurements. Also, the measurement of relay contact On Time has been simplified and expanded requiring no adjustments.
Code Parameter measurements have been made simpler and more accurate. No longer is it necessary to count pointer swings to measure. On Time can be measured on live signals as well as relay contacts. Peak levels can be determined quickly and automatically. Adjustments to the code equipment peak level can be made without constantly readjusting the Test Set.
Features
Applications
Ideal for the following applications: Rapid Transit, Commuter Trains, Passenger Railroads
DC Voltage | |
---|---|
Ranges | 0.6, 3, 15, 60, and 300 VDC |
Accuracy | ±1.5% of full scale |
Sensitivity | 1000 Ohms per Volt |
DC Milliamps | |
Ranges | 15, 60, and 300 mA DC |
Accuracy | ±1.5% of full scale |
Burden Volts | 60 mV nominal |
AC Voltage | |
Ranges | 1.5, 3, 15, 150, 300, and 600 VAC |
Accuracy | ±3.0% of full scale |
Sensitivity | 288 Ohms per Volt |
AC Amps | |
Ranges | 1.5, 6, and 30 Amps AC |
Accuracy | ±3.0% of full scale |
Burden Volts | 60 mV nominal |
Meter Movement | |
Electrical | 100 µA ±1% at full scale |
Construction | Taut band, shock mounted, mirrored scale |
DC Voltage | |
---|---|
Ranges | 0.6, 3, 15, 60, and 300 VDC |
Accuracy | ±1.5% of full scale |
Sensitivity | 1000 Ohms per Volt |
DC Milliamps | |
Ranges | 15, 60, and 300 mA DC |
Accuracy | ±1.5% of full scale |
Burden Volts | 60 mV nominal |
AC Voltage | |
Ranges | 1.5, 3, 15, 150, 300, and 600 VAC |
Accuracy | ±3.0% of full scale |
Sensitivity | 288 Ohms per Volt |
AC Amps | |
Ranges | 1.5, 6, and 30 Amps AC |
Accuracy | ±3.0% of full scale |
Burden Volts | 60 mV nominal |
Meter Movement | |
Electrical | 100 µA ±1% at full scale |
Construction | Taut band, shock mounted, mirrored scale |