The carbon monoxide sensor has a built in filter that can filter NO (Nitric Oxide), NO2 (Nitrogen Dioxide), NOX (Combination of NO and NO2 which helps prevent cross sensitivity sensors).
The carbon monoxide sensor has a built in filter that can filter NO (Nitric Oxide), NO2 (Nitrogen Dioxide), NOX (Combination of NO and NO2 which helps prevent cross sensitivity sensors).
Flue Gases in gas, oil fired equipment including high efficiency furnaces and condensing boilers can all be tested with the analyzer.
Features
Prevent damage to your sensor
Carbon Monoxide (CO) Measurement |
Range 0 to 10,000 ppm Resolution 1 ppm Accuracy ±5ppm or 5% of reading whichever is greater |
Oxygen (02) Measurement | Range 0 to 25% Resolution 0.1% Accuracy ±0.3% |
Carbon Dioxide (CO2) | Range 0 to 25% Resolution 0.1% Calculated Value |
Nitric Oxide Measurement | N/A |
NOX Measurement | N/A |
Temperature Measurement | Range -40 to 1472°F, or -40 to 800°C Resolution 1°F or °C Accuracy (K-type) ±0.3%, ±2°F or ±1°C |
Draft/Pressure Measurement |
Selectable Ranges mBar,kPa, and inH2O Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H2O Resolution 0.001 inH2O Accuracy ±0/5% fsd |
Gross/Net Efficiency | Range 0 to 100% Resolution 0.1% Calculated Value |
CO/CO2 Ratio | Range 0 to 0.999 Resolution 0.001 Calculated Value |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Battery Type | 1.5V AA (3) |
Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
Display Type | Backlit 3 line LCD |
Data Storage | 50 Locations |
Data Logging | N/A |
Print Capability | Yes, via optional IR printer (A740) |
PC Communication | N/A |
Date and Time Function | 24 Hour Real Time Clock |
Dimensions | 200mm x 90mm x 60mm |
Weight | 500g |
Conformity | BS7927 (and the draft BS7967) |
Carbon Monoxide (CO) Measurement |
Range 0 to 10,000 ppm Resolution 1 ppm Accuracy ±5ppm or 5% of reading whichever is greater |
Oxygen (02) Measurement | Range 0 to 25% Resolution 0.1% Accuracy ±0.3% |
Carbon Dioxide (CO2) | Range 0 to 25% Resolution 0.1% Calculated Value |
Nitric Oxide Measurement | N/A |
NOX Measurement | N/A |
Temperature Measurement | Range -40 to 1472°F, or -40 to 800°C Resolution 1°F or °C Accuracy (K-type) ±0.3%, ±2°F or ±1°C |
Draft/Pressure Measurement |
Selectable Ranges mBar,kPa, and inH2O Ranges -150 mBar to +150 mBar -15 kPa to +15 kPa -60 inH2O to +60 in H2O Resolution 0.001 inH2O Accuracy ±0/5% fsd |
Gross/Net Efficiency | Range 0 to 100% Resolution 0.1% Calculated Value |
CO/CO2 Ratio | Range 0 to 0.999 Resolution 0.001 Calculated Value |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Battery Type | 1.5V AA (3) |
Selectable Fuels | Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse |
Display Type | Backlit 3 line LCD |
Data Storage | 50 Locations |
Data Logging | N/A |
Print Capability | Yes, via optional IR printer (A740) |
PC Communication | N/A |
Date and Time Function | 24 Hour Real Time Clock |
Dimensions | 200mm x 90mm x 60mm |
Weight | 500g |
Conformity | BS7927 (and the draft BS7967) |