The monitor is compatible with the SCS static management program and monitors three key parameters that keep you aware of critical symptoms of ESD problems. These symptomps are ESD events, change in static voltage field, and ionizer performance.
The monitor is compatible with the SCS static management program and monitors three key parameters that keep you aware of critical symptoms of ESD problems. These symptomps are ESD events, change in static voltage field, and ionizer performance.
This EM aware monitor has ESD event continuous monitor that detects and measures the unique waveform generated by ESD events.
Features
Power | |
Power Adapter | Output: 7.5 VDC at 1.5 A |
100 to 240 VAC | Output Plug Polarization: Center positive |
50 to 60 Hz | Output Plug: 5.5 x 2.1 x 9.5 mm |
ESD Event Monitor | |
Measurement | Magnitude ESD event |
ESD Event Threshold | Default setting: 80 dBµV |
Raw Input Signal | 60 dBµV (1mV) to 134 dBµV (5.0 V) |
Filtering Function | ESD |
Static Voltage Monitor | |
Measurement | Static Voltage - Change of electrostatic field |
Static Voltage Setting Range | 12.5 V, 100 V, 250 V, 500 V, 1000 V, smart coefficient adjust |
Output | Ethernet |
Ionizer Voltage and Decay Monitor | |
Compatible Ionizer | Steady-State DC |
Maximum Decay Time Reading | 16 seconds maximum, typical |
Maximum Decay Test Voltage | ±5 V |
Connectivity | |
Input | SMA Connector for remote antenna |
Outputs | RJ45 connector for Ethernet output; 2-position terminal block for relay output |
General Specifications | |
Alarm | Buzzer |
Display | LCD |
Dimensions (antenna not included) | 3.17 x 2.25 x 1.26" (81 x 57 x 32 mm) |
Weight | 6.45 oz (183 g) |
Power | |
Power Adapter | Output: 7.5 VDC at 1.5 A |
100 to 240 VAC | Output Plug Polarization: Center positive |
50 to 60 Hz | Output Plug: 5.5 x 2.1 x 9.5 mm |
ESD Event Monitor | |
Measurement | Magnitude ESD event |
ESD Event Threshold | Default setting: 80 dBµV |
Raw Input Signal | 60 dBµV (1mV) to 134 dBµV (5.0 V) |
Filtering Function | ESD |
Static Voltage Monitor | |
Measurement | Static Voltage - Change of electrostatic field |
Static Voltage Setting Range | 12.5 V, 100 V, 250 V, 500 V, 1000 V, smart coefficient adjust |
Output | Ethernet |
Ionizer Voltage and Decay Monitor | |
Compatible Ionizer | Steady-State DC |
Maximum Decay Time Reading | 16 seconds maximum, typical |
Maximum Decay Test Voltage | ±5 V |
Connectivity | |
Input | SMA Connector for remote antenna |
Outputs | RJ45 connector for Ethernet output; 2-position terminal block for relay output |
General Specifications | |
Alarm | Buzzer |
Display | LCD |
Dimensions (antenna not included) | 3.17 x 2.25 x 1.26" (81 x 57 x 32 mm) |
Weight | 6.45 oz (183 g) |