Professional grade True RMS AC/DC clamp meter with peak hold function and digital analog bargraph. This product includes a Traceable Certificate with full Data and Uncertainties.

Professional grade True RMS AC/DC clamp meter with peak hold function and digital analog bargraph. This product includes a Traceable Certificate with full Data and Uncertainties.

Sale Price $254.00 USD
Regular Price $264.00 USD
Availability 5 Days
Quantity

Recommended Accessories


REED R5050-NIST Offers

This durable True RMS clamp meter is capable of measuring AC/DC current and voltage, resistance and frequency. Featuring a 4,000 count LCD display with a 42-segment analog bargraph, the R5050 includes a peak hold and min/max functions.

This product includes a Traceable Certificate with full Data and Uncertainties.

Features

  • Measures AC/DC current/voltage, resistance and frequency
  • 4000-count LCD display with analog bargraph
  • Low battery and overrange indicators
  • True RMS measurements
  • Min/Max, display hold, peak hold and relative mode
  • Diode test and continuity check functions
  • Cat. III 600V, Cat. II 1000V safety rating

REED R5050 Specifications

AC/DC Current
Range 40, 400, 1000A
Accuracy AC: ±(1.9% rdg. +5 dgt.)
DC: ±(2.5% rdg. +10 dgt.)
Resolution 0.01, 0.1, 1A
AC/DC Voltage
Range AC: 400, 750V
DC: 400, 1000V
Accuracy AC: ±(1.5% rdg. +5 dgt.)
DC: ±(1% rdg. +2 dgt.)
Resolution 0.1, 1V
Resistance
Range 400, 4000Ω
Accuracy ±(1% rdg. +3 dgt.)
0.1, 1Ω
Frequency
Range 4kHz, 10kHz
Accuracy ±(0.1% rdg. +1 dgt.)
Resolution 1Hz, 10Hz
General Specifications
Range Selection Autoranging / Manual
True RMS Yes 
Display 4,000 count LCD display
Display Hold Yes
Max/Min Yes
Peak Hold Yes
Zero Push Button Adjustment Yes
Relative Mode Yes
Diode Test Yes
Analog Bargraph Yes (42-segment)
Continuity Check Audible signal if resistance <100Ω
Autoshut off Yes (after 30 mins)
Power Supply 9V Battery
Low Battery Indicator Yes
Jaw Opening 1.5" (40mm), up to 500 MCM
Overvoltage Category CAT. III 600V, CAT. II 1000V
Product Certifications CE
Operating Temperature 32 to 104°F (0 to 40°C)
Storage Temperature 14 to 140°F (-10 to 60°C)
Dimensions 9.5x 2.6 x 1.4" (242 x 66 x 36 mm)
Weight 14oz (400g)
Click here for complete specifications on the REED R5050-NIST

What's included with the REED R5050-NIST

  • TRMS AC/DC Clamp Meter
  • Traceable Certificate with full Data and Uncertainties
  • Test Leads
  • Battery
  • Soft Carrying Case

How To: Use a Line Splitter to Measure Current/Amperage


A quick and easy step-by-step guide on how to measure the current from your outlets using a line splitter. For the purpose of this video, we'll be using the R5400 AC Line Splitter and the R5020 AC Clamp Meter. These steps will work for most line splitters.

Ideal Applications for the REED R5050

Industrial maintenance teams performing scheduled and preventative maintenance on electro-mechanical equipment and systems.

Facilities, building maintenance and electricians looking to troubleshoot electrical equipment installation problems.

Click on a category to view a selection of compatible accessories with the REED R5050 1000A True RMS AC/DC Clamp Meter, .

REED R5400 Line Splitter R5400
Provides safe measurements of current without the need to separate conductors.




REED CA-05A Medium Soft Carrying Case CA-05A
Features a main instrument compartment and a side pouch for accessories.




REED R1000 Safety Test Lead Set R1000
Right angle and straight end flexible leads with shrouded banana plugs.




REED R1020 Fused Test Lead Set R1020
Ergonomic comfort grip.




Ask a question about REED R5050 1000A True RMS AC/DC Clamp Meter,

Customer Reviews for the REED R5050-NIST

REED R5050-NIST Offers

This durable True RMS clamp meter is capable of measuring AC/DC current and voltage, resistance and frequency. Featuring a 4,000 count LCD display with a 42-segment analog bargraph, the R5050 includes a peak hold and min/max functions.

This product includes a Traceable Certificate with full Data and Uncertainties.

Features

  • Measures AC/DC current/voltage, resistance and frequency
  • 4000-count LCD display with analog bargraph
  • Low battery and overrange indicators
  • True RMS measurements
  • Min/Max, display hold, peak hold and relative mode
  • Diode test and continuity check functions
  • Cat. III 600V, Cat. II 1000V safety rating

REED R5050 Specifications

AC/DC Current
Range 40, 400, 1000A
Accuracy AC: ±(1.9% rdg. +5 dgt.)
DC: ±(2.5% rdg. +10 dgt.)
Resolution 0.01, 0.1, 1A
AC/DC Voltage
Range AC: 400, 750V
DC: 400, 1000V
Accuracy AC: ±(1.5% rdg. +5 dgt.)
DC: ±(1% rdg. +2 dgt.)
Resolution 0.1, 1V
Resistance
Range 400, 4000Ω
Accuracy ±(1% rdg. +3 dgt.)
0.1, 1Ω
Frequency
Range 4kHz, 10kHz
Accuracy ±(0.1% rdg. +1 dgt.)
Resolution 1Hz, 10Hz
General Specifications
Range Selection Autoranging / Manual
True RMS Yes 
Display 4,000 count LCD display
Display Hold Yes
Max/Min Yes
Peak Hold Yes
Zero Push Button Adjustment Yes
Relative Mode Yes
Diode Test Yes
Analog Bargraph Yes (42-segment)
Continuity Check Audible signal if resistance <100Ω
Autoshut off Yes (after 30 mins)
Power Supply 9V Battery
Low Battery Indicator Yes
Jaw Opening 1.5" (40mm), up to 500 MCM
Overvoltage Category CAT. III 600V, CAT. II 1000V
Product Certifications CE
Operating Temperature 32 to 104°F (0 to 40°C)
Storage Temperature 14 to 140°F (-10 to 60°C)
Dimensions 9.5x 2.6 x 1.4" (242 x 66 x 36 mm)
Weight 14oz (400g)
Click here for complete specifications on the REED R5050-NIST

What's included with the REED R5050-NIST

  • TRMS AC/DC Clamp Meter
  • Traceable Certificate with full Data and Uncertainties
  • Test Leads
  • Battery
  • Soft Carrying Case

How To: Use a Line Splitter to Measure Current/Amperage


A quick and easy step-by-step guide on how to measure the current from your outlets using a line splitter. For the purpose of this video, we'll be using the R5400 AC Line Splitter and the R5020 AC Clamp Meter. These steps will work for most line splitters.

Ideal Applications for the REED R5050

Industrial maintenance teams performing scheduled and preventative maintenance on electro-mechanical equipment and systems.

Facilities, building maintenance and electricians looking to troubleshoot electrical equipment installation problems.

Click on a category to view a selection of compatible accessories with the REED R5050 1000A True RMS AC/DC Clamp Meter, .

REED R5400 Line Splitter R5400
Provides safe measurements of current without the need to separate conductors.




REED CA-05A Medium Soft Carrying Case CA-05A
Features a main instrument compartment and a side pouch for accessories.




REED R1000 Safety Test Lead Set R1000
Right angle and straight end flexible leads with shrouded banana plugs.




REED R1020 Fused Test Lead Set R1020
Ergonomic comfort grip.




Ask a question about REED R5050 1000A True RMS AC/DC Clamp Meter,

Customer Reviews for the REED R5050-NIST

More REED Products

Calibration Lab