Unleash the full potential of biogas operations with this highly versatile and dependable analyzer kit, ideal for biogas, bio-methane, and landfill sites. This kit analyzes O2/CH4/CO2/H2S and biogas pressure and comes with a US landfill gas probe, an HC sniffer, a type-K thermocouple, a biogas sampling line, and an ABS carrying case.
Unleash the full potential of biogas operations with this highly versatile and dependable analyzer kit, ideal for biogas, bio-methane, and landfill sites. This kit analyzes O2/CH4/CO2/H2S and biogas pressure and comes with a US landfill gas probe, an HC sniffer, a type-K thermocouple, a biogas sampling line, and an ABS carrying case.
Features
Applications
Methane | Measuring method: NDIR Measuring range: 0 to 100% Resolution: 0.1% Repeatability: ±0.3% or 3% reading |
Oxygen (Long Life) | Measuring method: Electro-chemical Measuring range: 0 to 25% Resolution: 0.01% Repeatability: ±0.2% absolute |
Carbon Dioxide | Measuring method: NDIR Measuring range: 0 to 100% Resolution: 0.01% Repeatability: ±0.3% or 3% reading |
Hydrogen Sulfide | Measuring method: Electro-chemical Measuring range: 0 to 2000/5000 ppm Resolution: 1 ppm Repeatability: ±5 ppm or 5% (0 to 500 ppm), 1% (>500 ppm) reading |
Gas Flow Velocity | Measuring method: S-type probe 1 Measuring range: 1 to 100 m/s Resolution: 0.1 m/s Repeatability: ±0.2 m/s (2 to 10 m/s), ±0.5% (>10 m/s) |
Flow Rate | Measuring method: Calculated Measuring range: 0.1 to 6000 m3/s Resolution: 0.1 m3/s Repeatability: User settable cross section area |
Differential Temperature | Measuring method: NiCrNi Measuring range: -40 to 2192°F (-40 to 1200°C) Resolution: 1°F (-17.22°C) Repeatability: ±4°F (2°C), 0.5% reading |
Differential Pressure | Measuring method: Piezo Measuring range: ±120°H2O (300 hPa) Resolution: 0.01 hPa Repeatability: ±0.01°H2O (0.03 hPa), 1% reading |
Temperature | Operation: 41 to 113°F (5 to 45°C) maximum 95% RH, none condensing Storage: 4 to 122°F (-20 to 50°C) |
Data Storage | 32,000 data sets |
Interfaces | SD card reader, USB, IRDA, WLAN |
Biogas Sampling Line | ø0.11 x 0.07" (3 x 2 mm) viton with 16.4' (5m) length and stainless steel instrument gas inlet port |
Protection Class | IP 30 |
Power | Internal supply: Lithium-ion battery, 15 hours of operation time Mains supply: Wall plug unit 100 to 240 V AC, 50 to 60 Hz, 5 V DC, 1.2 A |
Dimensions | 4.45 x 8.82 x 2.13" (113 x 244 x 54 mm) |
Weight | Approximately 1.7 lbs (750 g) |
Click on a category to view a selection of compatible accessories with the MRU OPTIMAX Landfill Gas Analyzer Kit with US landfill gas probe and HC sniffer, O2/CH4/CO2/H2S.
Methane | Measuring method: NDIR Measuring range: 0 to 100% Resolution: 0.1% Repeatability: ±0.3% or 3% reading |
Oxygen (Long Life) | Measuring method: Electro-chemical Measuring range: 0 to 25% Resolution: 0.01% Repeatability: ±0.2% absolute |
Carbon Dioxide | Measuring method: NDIR Measuring range: 0 to 100% Resolution: 0.01% Repeatability: ±0.3% or 3% reading |
Hydrogen Sulfide | Measuring method: Electro-chemical Measuring range: 0 to 2000/5000 ppm Resolution: 1 ppm Repeatability: ±5 ppm or 5% (0 to 500 ppm), 1% (>500 ppm) reading |
Gas Flow Velocity | Measuring method: S-type probe 1 Measuring range: 1 to 100 m/s Resolution: 0.1 m/s Repeatability: ±0.2 m/s (2 to 10 m/s), ±0.5% (>10 m/s) |
Flow Rate | Measuring method: Calculated Measuring range: 0.1 to 6000 m3/s Resolution: 0.1 m3/s Repeatability: User settable cross section area |
Differential Temperature | Measuring method: NiCrNi Measuring range: -40 to 2192°F (-40 to 1200°C) Resolution: 1°F (-17.22°C) Repeatability: ±4°F (2°C), 0.5% reading |
Differential Pressure | Measuring method: Piezo Measuring range: ±120°H2O (300 hPa) Resolution: 0.01 hPa Repeatability: ±0.01°H2O (0.03 hPa), 1% reading |
Temperature | Operation: 41 to 113°F (5 to 45°C) maximum 95% RH, none condensing Storage: 4 to 122°F (-20 to 50°C) |
Data Storage | 32,000 data sets |
Interfaces | SD card reader, USB, IRDA, WLAN |
Biogas Sampling Line | ø0.11 x 0.07" (3 x 2 mm) viton with 16.4' (5m) length and stainless steel instrument gas inlet port |
Protection Class | IP 30 |
Power | Internal supply: Lithium-ion battery, 15 hours of operation time Mains supply: Wall plug unit 100 to 240 V AC, 50 to 60 Hz, 5 V DC, 1.2 A |
Dimensions | 4.45 x 8.82 x 2.13" (113 x 244 x 54 mm) |
Weight | Approximately 1.7 lbs (750 g) |
Click on a category to view a selection of compatible accessories with the MRU OPTIMAX Landfill Gas Analyzer Kit with US landfill gas probe and HC sniffer, O2/CH4/CO2/H2S.