Designed for extended temperature range use, this digital ground tester is ideally used as an outdoor instrument. Easy-to-use, this ground tester offers the basic functions required for ground system testing, including ground voltage measurement, and two clamps for Attached Rod Technique (ART), and stakeless testing.
Designed for extended temperature range use, this digital ground tester is ideally used as an outdoor instrument. Easy-to-use, this ground tester offers the basic functions required for ground system testing, including ground voltage measurement, and two clamps for Attached Rod Technique (ART), and stakeless testing.
Designed to negate the need for a shorting link when making two-pole measurements, this ground tester also offers labeled auxiliary controls used to select the test frequency (94, 105, 111, and 128 Hz), output voltage (50 or 25 V where local standards apply), and to switch the backlight on or off.
Features
Applications
Resistance Range | 0.01 Ω to 20 kΩ |
Resistance Accuracy | 2p Measurements: 2% ±3 digits 3p Measurements: 2% ±3 digits 4p Measurements: 2% ±3 digits ART Measurements: 5% ±3 digits Stakeless Measurements: 7% ±3 digits |
Maximum Probe Resistance | Rp limit: 200 kΩ (50 V output voltage) Rc limit: 200 kΩ (50 V output voltage) Limits reduced to 100 kΩ for 25 V output voltage Limits reduced to 5 kΩ for 0.01 Ω resolution |
Earth Voltage | Range: 0 to 100 V AC Accuracy: 2% ±2 V |
C Spike Check | Automatic |
P Spike Check | Automatic |
Noise | Check: Automatic Rejection: 40 V pk to pk |
Test | Frequency: 94, 105, 111 and 128 Hz Voltage: 25 or 50 V, user selectable (factory setting 50 V) Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V |
Display | 3½" digit high contrast LCD, backlit |
Battery | Type: 8 x 1.5 V AA cells Life: 3 hours, 700 consecutive tests |
Temperature Range | Operating: 5 to 131°F (-15 to 55°C) Storage: -40 to 158°F (-40 to 70°C) |
Humidity | 95% RH non-condensing at 104°F (40°C) |
Safety | EN61010-1 CAT IV 100 V |
Ingress Protection | IP54 |
Dimensions | 8 x 5.7 x 3.2" (203 x 148 x 78 mm) |
Weight | 2.20 lbs (1 kg) |
Designed for extended temperature range use, this digital ground tester is ideally used as an outdoor instrument. Easy-to-use, this ground tester offers the basic functions required for ground system testing, including variable frequency 2, 3, and 4 poles, Attached Rod Technique (ART), ground noise voltage measurement, and more.
Designed for measurements of AC currents up to 1000 A with a 1000:1 step-down ratio, this probe offers an accuracy of 0.3% error at full range and small phase shift at 0.7° at full range. Thanks to the high-permeability Ni-Fe alloy, this probe is reliable and achieves high performance every time.
Designed for stakeless testing and compatible with the DET4TC2 and DET4TCR2.
Selection Guide | DET4TD2 | DET4TR2 | DET4TC2 | DET4TCR2 | |
---|---|---|---|---|---|
Tests | 2-Pole Measurement | ||||
3-Pole Measurement | |||||
4-Pole Measurement | |||||
Soil Resistivity | |||||
ART (Attached Rod Technique) Capability | |||||
Stakeless (Clamp-on) Measurement Capability | |||||
Resistance Range | 0.01 to 20,000 Ω | 0.01 to 200,000 Ω | |||
Ground Voltage Range | 0 to 100 V | ||||
Ground Current Range (with ICLAMP) Capability | 0.5 mA to 19.9 A | ||||
Output | Selectable Voltage (25/50 V) | ||||
Test Frequency | 128 Hz | 94, 105, 111, 128 Hz | |||
Power Supply | Alkaline Batteries | ||||
Rechargeable Batteries | |||||
Noise Rejection | 40 V Peak-to-Peak | ||||
Safety Rating | CAT IV 100 V | ||||
Ingress Protection | Rated to IP54 | ||||
Included Accessories | Hard Carry Case | ||||
Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes | |||||
Certificate of Calibration | |||||
Warranty | 2 Year |
Click on a category to view a selection of compatible accessories with the Megger DET4TC2 4-Terminal Digital Ground Resistance Tester with ICLAMP and VCLAMP, 2/3/4 point testing.
Resistance Range | 0.01 Ω to 20 kΩ |
Resistance Accuracy | 2p Measurements: 2% ±3 digits 3p Measurements: 2% ±3 digits 4p Measurements: 2% ±3 digits ART Measurements: 5% ±3 digits Stakeless Measurements: 7% ±3 digits |
Maximum Probe Resistance | Rp limit: 200 kΩ (50 V output voltage) Rc limit: 200 kΩ (50 V output voltage) Limits reduced to 100 kΩ for 25 V output voltage Limits reduced to 5 kΩ for 0.01 Ω resolution |
Earth Voltage | Range: 0 to 100 V AC Accuracy: 2% ±2 V |
C Spike Check | Automatic |
P Spike Check | Automatic |
Noise | Check: Automatic Rejection: 40 V pk to pk |
Test | Frequency: 94, 105, 111 and 128 Hz Voltage: 25 or 50 V, user selectable (factory setting 50 V) Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V |
Display | 3½" digit high contrast LCD, backlit |
Battery | Type: 8 x 1.5 V AA cells Life: 3 hours, 700 consecutive tests |
Temperature Range | Operating: 5 to 131°F (-15 to 55°C) Storage: -40 to 158°F (-40 to 70°C) |
Humidity | 95% RH non-condensing at 104°F (40°C) |
Safety | EN61010-1 CAT IV 100 V |
Ingress Protection | IP54 |
Dimensions | 8 x 5.7 x 3.2" (203 x 148 x 78 mm) |
Weight | 2.20 lbs (1 kg) |
Designed for extended temperature range use, this digital ground tester is ideally used as an outdoor instrument. Easy-to-use, this ground tester offers the basic functions required for ground system testing, including variable frequency 2, 3, and 4 poles, Attached Rod Technique (ART), ground noise voltage measurement, and more.
Designed for measurements of AC currents up to 1000 A with a 1000:1 step-down ratio, this probe offers an accuracy of 0.3% error at full range and small phase shift at 0.7° at full range. Thanks to the high-permeability Ni-Fe alloy, this probe is reliable and achieves high performance every time.
Designed for stakeless testing and compatible with the DET4TC2 and DET4TCR2.
Selection Guide | DET4TD2 | DET4TR2 | DET4TC2 | DET4TCR2 | |
---|---|---|---|---|---|
Tests | 2-Pole Measurement | ||||
3-Pole Measurement | |||||
4-Pole Measurement | |||||
Soil Resistivity | |||||
ART (Attached Rod Technique) Capability | |||||
Stakeless (Clamp-on) Measurement Capability | |||||
Resistance Range | 0.01 to 20,000 Ω | 0.01 to 200,000 Ω | |||
Ground Voltage Range | 0 to 100 V | ||||
Ground Current Range (with ICLAMP) Capability | 0.5 mA to 19.9 A | ||||
Output | Selectable Voltage (25/50 V) | ||||
Test Frequency | 128 Hz | 94, 105, 111, 128 Hz | |||
Power Supply | Alkaline Batteries | ||||
Rechargeable Batteries | |||||
Noise Rejection | 40 V Peak-to-Peak | ||||
Safety Rating | CAT IV 100 V | ||||
Ingress Protection | Rated to IP54 | ||||
Included Accessories | Hard Carry Case | ||||
Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes | |||||
Certificate of Calibration | |||||
Warranty | 2 Year |
Click on a category to view a selection of compatible accessories with the Megger DET4TC2 4-Terminal Digital Ground Resistance Tester with ICLAMP and VCLAMP, 2/3/4 point testing.