Automatically upload real-time temperature data with this vaccine kit, featuring storage of up to 16,129 temperature readings. This kit comes with a low-temperature recorder, two external probes, two buffer bottles, a wall mount bracket, and a calibration certificate.
Automatically upload real-time temperature data with this vaccine kit, featuring storage of up to 16,129 temperature readings. This kit comes with a low-temperature recorder, two external probes, two buffer bottles, a wall mount bracket, and a calibration certificate.
See if temperature excursions have occurred at a glance with this vaccine kit, designed to show the current day and up to the previous 29 days. Additionally, this kit features a built-in alarm if temperature readings are outside pre-set limits.
Features
Applications
Sensor Measurement Range | -130 to 104°F (-90 to 40°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) Storage: 32 to 104°F (0 to 40°C) |
Rated Temperature Reading Accuracy | Better than ±32.9°F (±0.5°C) for -4 to 50°F (-20 to 10°C) Better than ±33.26°F (±0.7°C) for -58 to -4°F (-50 to -20°C) and 50 to 86°F (10 to 30°C) Better than ±33.8°F (±1°C) for -112 to -58°F (-80 to -50°C ) and 86 to 104°F (30 to 40°C) Better than ±35.24°F (±1.8°C) for -130 to -112°F (-90 to -80°C) |
Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1m/s) for ST10S type |
Rated Temperature Reading Resolution | 0.2°F (0.1°C) for measurements -112 to 50°F (-80 to 10°C) 0.4°F (0.2°C) for measurements 50 to 68°F (10 to 20°C) and -130 to -112°F (-90 to -80°C) 0.5°F (0.3°C) for measurements 68 to 86°F (20 to 30°C) 0.5°F (0.3°C) for measurements 86 to 104°F (30 to 40°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag® |
Recording Capacity | 16,129 temperature readings. 67 days at 6 minute logging. Day summary statistics memory (For display on LCD): Up to 30 days of minimum/maximum/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to 18 hours |
Logging Start Options | Push button start (With configurable start delay from 1 minute to 72 hours) or specific date and time |
Download Time | Typically with full memory (16,129 readings) in less than 10 seconds |
Environmental | IP51 (When vertically mounted or hung with USB dust-cap in place) |
Calibration | Factory calibrated using NIST equivalent reference equipment. Calibration certificate available on request |
Connection Interface | USB 2.0/micro-USB plug |
WiFi | IEEE 802.11 / WPA/WPA2 security |
Case Material | Polycarbonate |
Power | Source: 5 V via micro USB socket or two 1.5 V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only). Life: Device should normally be powered via USB. AAA batteries provide backup power for up to 2 months |
Dimensions | 5.55 x 2.83 x 0.7" (141 x 72 x 18 mm) |
Weight | 0.34 lbs (158 g) with AAA batteries, 0.29 lbs (132 g) excluding probe and AAA batteries |
Click on a category to view a selection of compatible accessories with the LogTag UTREL30-16-WIFI WiFi Vaccine Kit, with two external probes, -130 to 104°F.
Sensor Measurement Range | -130 to 104°F (-90 to 40°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) Storage: 32 to 104°F (0 to 40°C) |
Rated Temperature Reading Accuracy | Better than ±32.9°F (±0.5°C) for -4 to 50°F (-20 to 10°C) Better than ±33.26°F (±0.7°C) for -58 to -4°F (-50 to -20°C) and 50 to 86°F (10 to 30°C) Better than ±33.8°F (±1°C) for -112 to -58°F (-80 to -50°C ) and 86 to 104°F (30 to 40°C) Better than ±35.24°F (±1.8°C) for -130 to -112°F (-90 to -80°C) |
Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1m/s) for ST10S type |
Rated Temperature Reading Resolution | 0.2°F (0.1°C) for measurements -112 to 50°F (-80 to 10°C) 0.4°F (0.2°C) for measurements 50 to 68°F (10 to 20°C) and -130 to -112°F (-90 to -80°C) 0.5°F (0.3°C) for measurements 68 to 86°F (20 to 30°C) 0.5°F (0.3°C) for measurements 86 to 104°F (30 to 40°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag® |
Recording Capacity | 16,129 temperature readings. 67 days at 6 minute logging. Day summary statistics memory (For display on LCD): Up to 30 days of minimum/maximum/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to 18 hours |
Logging Start Options | Push button start (With configurable start delay from 1 minute to 72 hours) or specific date and time |
Download Time | Typically with full memory (16,129 readings) in less than 10 seconds |
Environmental | IP51 (When vertically mounted or hung with USB dust-cap in place) |
Calibration | Factory calibrated using NIST equivalent reference equipment. Calibration certificate available on request |
Connection Interface | USB 2.0/micro-USB plug |
WiFi | IEEE 802.11 / WPA/WPA2 security |
Case Material | Polycarbonate |
Power | Source: 5 V via micro USB socket or two 1.5 V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only). Life: Device should normally be powered via USB. AAA batteries provide backup power for up to 2 months |
Dimensions | 5.55 x 2.83 x 0.7" (141 x 72 x 18 mm) |
Weight | 0.34 lbs (158 g) with AAA batteries, 0.29 lbs (132 g) excluding probe and AAA batteries |
Click on a category to view a selection of compatible accessories with the LogTag UTREL30-16-WIFI WiFi Vaccine Kit, with two external probes, -130 to 104°F.