Lascar SGD ADPT-420 Current Loop Conditioning Module for the PanelPilot M series displays

Model: SGD ADPT-420

Lascar SGD ADPT-420 Current Loop Conditioning Module for the PanelPilot M series displays

Model: SGD ADPT-420

Directly interface with a compatible display with current loop conditioning module which features two isolated input channels and takes its power directly from the SGD meter. Current loop connection is via screw terminals and this module is ideal to work with a PanelPilot M series display.

Directly interface with a compatible display with current loop conditioning module which features two isolated input channels and takes its power directly from the SGD meter. Current loop connection is via screw terminals and this module is ideal to work with a PanelPilot M series display.

Your Price $57.99 USD
Availability 2 to 3 Weeks
Quantity

Lascar SGD ADPT-420 Offers

Provides dual channel 4 to 20 mA galvanic isolation.

Features

  • Measures 4 to 20 mA current loops (nom. loop voltage 24 V DC)
  • Two separate, isolated, channels
  • Ideal for measuring Command and Position on the same display
  • Powered from SGD meter
  • Simple mounting on back of SGD header
  • Application download from PanelPilot website
  • Works with any PanelPilot voltage configuration
  • Operating voltage of 12 to 30 V DC
  • Does not need floating PSU with respect to current loops
  • Each current loop channel is isolated from each other as well as the PanelPilot

Lascar SGD ADPT-420 Specifications

Resolution 0.1%
Supply Voltage: 6 to 30 V DC
Current: 35 to 190 mA
Number of Isolated Input Channels 2
Measurement Range (24 V DC Loop Powered) 4 to 20 mA
Loop Volt Drop 0 to 5 V
Click here for complete specifications on the Lascar SGD ADPT-420

What's included with the Lascar SGD ADPT-420

  • Current Loop Conditioning Module

Ask a question about Lascar SGD ADPT-420 Current Loop Conditioning Module for the PanelPilot M series displays

Customer Reviews for the Lascar SGD ADPT-420

Lascar SGD ADPT-420 Offers

Provides dual channel 4 to 20 mA galvanic isolation.

Features

  • Measures 4 to 20 mA current loops (nom. loop voltage 24 V DC)
  • Two separate, isolated, channels
  • Ideal for measuring Command and Position on the same display
  • Powered from SGD meter
  • Simple mounting on back of SGD header
  • Application download from PanelPilot website
  • Works with any PanelPilot voltage configuration
  • Operating voltage of 12 to 30 V DC
  • Does not need floating PSU with respect to current loops
  • Each current loop channel is isolated from each other as well as the PanelPilot

Lascar SGD ADPT-420 Specifications

Resolution 0.1%
Supply Voltage: 6 to 30 V DC
Current: 35 to 190 mA
Number of Isolated Input Channels 2
Measurement Range (24 V DC Loop Powered) 4 to 20 mA
Loop Volt Drop 0 to 5 V
Click here for complete specifications on the Lascar SGD ADPT-420

What's included with the Lascar SGD ADPT-420

  • Current Loop Conditioning Module

Ask a question about Lascar SGD ADPT-420 Current Loop Conditioning Module for the PanelPilot M series displays

Customer Reviews for the Lascar SGD ADPT-420