Kyoritsu 2002PA Clamp Meter, 2000A/1000V

Model: 2002PA | Order No: KEW2002PA

Kyoritsu 2002PA Clamp Meter, 2000A/1000V

Model: 2002PA | Order No: KEW2002PA

Can measure large AC current up to 2000A. 55mm-diameter large tear drop shaped jaws.

Can measure large AC current up to 2000A. 55mm-diameter large tear drop shaped jaws.

Sale Price $180.40 USD
Regular Price $205.00 USD
Availability 1 in Stock
Quantity

Traceable In-House Calibration Certificate for your KEW2002PA Clamp Meter

Traceable In-House Calibration Certificate for your KEW2002PA Clamp Meter

Kyoritsu 2002PA Clamp Meter Offers

Features

  • Tear-drop-shaped jaws for ease of use in crowded cable areas and other tight places
  • Provides a wide measuring range from 0 up to 2000A
  • Terminal cover to avoid the use of an incorrect terminal
  • Measures current variation as short as 10ms with peak-hold feature
  • Provides output to a chart recorder for current variation recording
  • Data hold function to allow easy readings in dimly lit or hard-to-read locations
  • Sleep feature to conserve battery power
  • Permits easy continuity check with a beeper
  • Provides a dynamic range of 4,000 counts full scale
  • Provides wide measuring range of voltage and resistance in autoranging
  • Wide frequency range from 40Hz to 1kHz (Current measuring range: (0-1500A)
  • Transformer jaws fitted with guard to further improve safety
  • Protected throughout by double or reinforced insulation

Kyoritsu 2002PA Specifications

Functional Specifications
Current Ranges 20 A, 200 A, 200 A, AC RMS
Output Sensitivity (AC-coupled) 100 mV, 10 mV, 1 mV, 1 mV per A
Load Impedance 100 kΩ minimum
Accuracy At 25°C ±1% of range (45 Hz to 65 Hz)
Linearity 10% to 100% of range ±0.2% of reading
Noise 8mV AC RMS (30 A); 2mV AC RMS (300 A, 3000 A)
Frequency Range 10 Hz to 20 kHz (-3 dB)
Phase Error < ±1-3/4 (45 Hz to 65 Hz); ± 10 3/4 (at 20 kHz)
Position Sensitivity With cable > 25 mm from the coupling ± 2 % of range
External Field With Cable > 200 mm from the head ± 1 % of range
Power Supply 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient ± 0.08% of reading per °C
General Specifications
Head Circumference 610 mm (24 in)
Head Cable Diameter 14.3 mm (0.56")
Head Bend Radius 38.1 mm (1.5")
Cable Length (head to electronics) 2 m (6.56 ft)
Output Connection Molded 4mm safety plugs (not integrated)
Weight 180g (6.34 oz) (head); 190 g (6.70 oz) (electronics)
Safety Standards EN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
600 VRMS, Category III, Pollution Degree 2
EMC Standards EN 61326: 1998 +A1, A2, & A3
Dimensions 116 x 68.5 x 30mm (4.56 x 2.69 x 1.18")
Click here for complete specifications on the Kyoritsu 2002PA

What's included with the Kyoritsu 2002PA

  • Digital Clamp-Meter Test Lead Set
  • 2X Output Plug
  • 2X 1.5V AA Batteries
  • Carrying Case
  • Instructions

Ask a question about Kyoritsu 2002PA Clamp Meter, 2000A/1000V

Customer Reviews for the Kyoritsu 2002PA

Kyoritsu 2002PA Clamp Meter Offers

Features

  • Tear-drop-shaped jaws for ease of use in crowded cable areas and other tight places
  • Provides a wide measuring range from 0 up to 2000A
  • Terminal cover to avoid the use of an incorrect terminal
  • Measures current variation as short as 10ms with peak-hold feature
  • Provides output to a chart recorder for current variation recording
  • Data hold function to allow easy readings in dimly lit or hard-to-read locations
  • Sleep feature to conserve battery power
  • Permits easy continuity check with a beeper
  • Provides a dynamic range of 4,000 counts full scale
  • Provides wide measuring range of voltage and resistance in autoranging
  • Wide frequency range from 40Hz to 1kHz (Current measuring range: (0-1500A)
  • Transformer jaws fitted with guard to further improve safety
  • Protected throughout by double or reinforced insulation

Kyoritsu 2002PA Specifications

Functional Specifications
Current Ranges 20 A, 200 A, 200 A, AC RMS
Output Sensitivity (AC-coupled) 100 mV, 10 mV, 1 mV, 1 mV per A
Load Impedance 100 kΩ minimum
Accuracy At 25°C ±1% of range (45 Hz to 65 Hz)
Linearity 10% to 100% of range ±0.2% of reading
Noise 8mV AC RMS (30 A); 2mV AC RMS (300 A, 3000 A)
Frequency Range 10 Hz to 20 kHz (-3 dB)
Phase Error < ±1-3/4 (45 Hz to 65 Hz); ± 10 3/4 (at 20 kHz)
Position Sensitivity With cable > 25 mm from the coupling ± 2 % of range
External Field With Cable > 200 mm from the head ± 1 % of range
Power Supply 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient ± 0.08% of reading per °C
General Specifications
Head Circumference 610 mm (24 in)
Head Cable Diameter 14.3 mm (0.56")
Head Bend Radius 38.1 mm (1.5")
Cable Length (head to electronics) 2 m (6.56 ft)
Output Connection Molded 4mm safety plugs (not integrated)
Weight 180g (6.34 oz) (head); 190 g (6.70 oz) (electronics)
Safety Standards EN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
600 VRMS, Category III, Pollution Degree 2
EMC Standards EN 61326: 1998 +A1, A2, & A3
Dimensions 116 x 68.5 x 30mm (4.56 x 2.69 x 1.18")
Click here for complete specifications on the Kyoritsu 2002PA

What's included with the Kyoritsu 2002PA

  • Digital Clamp-Meter Test Lead Set
  • 2X Output Plug
  • 2X 1.5V AA Batteries
  • Carrying Case
  • Instructions

Ask a question about Kyoritsu 2002PA Clamp Meter, 2000A/1000V

Customer Reviews for the Kyoritsu 2002PA

More Kyoritsu Products

Calibration Lab