Features five functions in one unit. Measures AC current, AC voltage and Resistance, DC voltage, and temperature with the optional temperature probe.
Features five functions in one unit. Measures AC current, AC voltage and Resistance, DC voltage, and temperature with the optional temperature probe.
Features
AC | |
Ranges | AC A: 6/15/60/150/300A AC V: 150/300/600V |
Accuracy | ±3% of FS |
DC | |
Range | 60V |
Accuracy | ±3% of FS |
Resistance | |
Range | 1/10k± (25/250Ω mid-scale) |
Accuracy | ±2% of scale length |
Temperature | |
Range | -20 to 150°C (with the use of Temperature Probe 7060) |
Accuracy | ±5°C (0 to 100°C) ±10°C (Other Ranges) |
General Specifications | |
Conductor Size | Ø33mm max. |
Frequency Response | 50/60Hz |
Safety Standard | IEC 61010-1 CAT III 300V Pollution Degree 2 IEC 61010-2-031 IEC 61010-2-032 |
Withstand Voltage | 3700V AC for 1 minute |
Power Source | R6 AA 1.5V battery |
Dimensions | 193 x 78 x 39 mm |
Weight | Approx. 275 g |
AC | |
Ranges | AC A: 6/15/60/150/300A AC V: 150/300/600V |
Accuracy | ±3% of FS |
DC | |
Range | 60V |
Accuracy | ±3% of FS |
Resistance | |
Range | 1/10k± (25/250Ω mid-scale) |
Accuracy | ±2% of scale length |
Temperature | |
Range | -20 to 150°C (with the use of Temperature Probe 7060) |
Accuracy | ±5°C (0 to 100°C) ±10°C (Other Ranges) |
General Specifications | |
Conductor Size | Ø33mm max. |
Frequency Response | 50/60Hz |
Safety Standard | IEC 61010-1 CAT III 300V Pollution Degree 2 IEC 61010-2-031 IEC 61010-2-032 |
Withstand Voltage | 3700V AC for 1 minute |
Power Source | R6 AA 1.5V battery |
Dimensions | 193 x 78 x 39 mm |
Weight | Approx. 275 g |