Kyoritsu 1052 Mean/RMS Switch Multimeter

Model: 1052 | Order No: KEW1052

Kyoritsu 1052 Mean/RMS Switch Multimeter

Model: 1052 | Order No: KEW1052

TRMS or MEAN value detection mode can be selected. Features a large data internal memory: 1,600 data (logging), 100 data (manual).

TRMS or MEAN value detection mode can be selected. Features a large data internal memory: 1,600 data (logging), 100 data (manual).

Sale Price $292.16 USD
Regular Price $332.00 USD
Availability 2 to 3 Weeks
Quantity

Traceable In-House Calibration Certificate for your KEW1052 Mean/RMS Switch Multimeter

Traceable In-House Calibration Certificate for your KEW1052 Mean/RMS Switch Multimeter

Kyoritsu 1052 Offers

Features

  • 0.09% basic DC accuracy
  • Large display with 6,000 counts
  • True RMS Measurements
  • True RMS or MEAN value detection mode can be selected
  • Low-pass filter for motor drive measurements
  • User calibration function
  • Selection of the reading mode
  • Sensor mode
  • Auto Hold function
  • Relative and Percentage calculation
  • Minimum/Maximum/Average function
  • Complies with IEC 61010-1 CAT.IV 600V, CAT.III 1000V
  • Safety shutters to prevent incorrect test leads insertion in current terminals
  • Very wide operating temperature range
  • High specs UL standard fuses for extra safety
  • Over molding case
  • Large internal memory to store test data

Kyoritsu 1052 Specifications

DC V
Range 600.0mV/6.000V/60.00V/600.0V/1000V
Accuracy 600.0mV/6.000V/60.00V/600.0V: 0.09+2
1000V: 0.15+2
Input Impedance 600.0mV/60.00V/600.0V/1000V: 10MΩ
6.000V: 11MΩ
Overload Protection 1000V DC
1000V rms AC
AC V
Range 600.0mV/6.000V/60.00V/600.0V/1000V
Accuracy 50/60Hz: 0.5+5
40 to 500Hz: 1+5
500Hz to 1kHz: 1.5+5 (except for 1000V)
Input Impedance 600.0mV: 10MΩ<200pF
6.000V: 11MΩ<50pF
60.00V/600.0V/1000V: 10MΩ<50pF
Overload Protection 1000V rms AC
1000V DC
DC A
Range 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A
Accuracy 600.0µA/6000µA/60.00mA: 0.2+2
440.0mA/6.000A/10.00A: 0.5+5
Voltage Drop 600.0µA/6000µA: <0.12mV/µA
60.00mA/440.0mA: <3.3mV/mA
6.000A/10.00A: <0.1V/A
Overload Protection 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse
6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse
AC A
Range 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A
Accuracy 50/60Hz: 0.75+5
40Hz to 1kHz: 1.5+5
Voltage Drop 600.0µA/6000µA: <0.12mV/µA
60.00mA/440.0mA: <3.3mV/mA
6.000A/10.00A: <0.1V/A
Overload Protection 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse
6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse
Click here for complete specifications on the Kyoritsu 1052

What's included with the Kyoritsu 1052

  • Multimeter
  • Test Leads
  • 440mA/1000V Fuse
  • 10A/1000V Fuse
  • 4 x R6 Battery
  • Instruction Manual

Ask a question about Kyoritsu 1052 Mean/RMS Switch Multimeter

Customer Reviews for the Kyoritsu 1052

Kyoritsu 1052 Offers

Features

  • 0.09% basic DC accuracy
  • Large display with 6,000 counts
  • True RMS Measurements
  • True RMS or MEAN value detection mode can be selected
  • Low-pass filter for motor drive measurements
  • User calibration function
  • Selection of the reading mode
  • Sensor mode
  • Auto Hold function
  • Relative and Percentage calculation
  • Minimum/Maximum/Average function
  • Complies with IEC 61010-1 CAT.IV 600V, CAT.III 1000V
  • Safety shutters to prevent incorrect test leads insertion in current terminals
  • Very wide operating temperature range
  • High specs UL standard fuses for extra safety
  • Over molding case
  • Large internal memory to store test data

Kyoritsu 1052 Specifications

DC V
Range 600.0mV/6.000V/60.00V/600.0V/1000V
Accuracy 600.0mV/6.000V/60.00V/600.0V: 0.09+2
1000V: 0.15+2
Input Impedance 600.0mV/60.00V/600.0V/1000V: 10MΩ
6.000V: 11MΩ
Overload Protection 1000V DC
1000V rms AC
AC V
Range 600.0mV/6.000V/60.00V/600.0V/1000V
Accuracy 50/60Hz: 0.5+5
40 to 500Hz: 1+5
500Hz to 1kHz: 1.5+5 (except for 1000V)
Input Impedance 600.0mV: 10MΩ<200pF
6.000V: 11MΩ<50pF
60.00V/600.0V/1000V: 10MΩ<50pF
Overload Protection 1000V rms AC
1000V DC
DC A
Range 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A
Accuracy 600.0µA/6000µA/60.00mA: 0.2+2
440.0mA/6.000A/10.00A: 0.5+5
Voltage Drop 600.0µA/6000µA: <0.12mV/µA
60.00mA/440.0mA: <3.3mV/mA
6.000A/10.00A: <0.1V/A
Overload Protection 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse
6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse
AC A
Range 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A
Accuracy 50/60Hz: 0.75+5
40Hz to 1kHz: 1.5+5
Voltage Drop 600.0µA/6000µA: <0.12mV/µA
60.00mA/440.0mA: <3.3mV/mA
6.000A/10.00A: <0.1V/A
Overload Protection 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse
6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse
Click here for complete specifications on the Kyoritsu 1052

What's included with the Kyoritsu 1052

  • Multimeter
  • Test Leads
  • 440mA/1000V Fuse
  • 10A/1000V Fuse
  • 4 x R6 Battery
  • Instruction Manual

Ask a question about Kyoritsu 1052 Mean/RMS Switch Multimeter