Ideal for measuring low-voltage equipment, this digital multimeter features a wide range for various test fields and meets international safety standards IEC61010-1 CAT III 300 V/CAT II 600 V. In addition, it has True RMS, 6040 counts with bar graph display, MIN/MAX, and REL (relative value) functions.
Ideal for measuring low-voltage equipment, this digital multimeter features a wide range for various test fields and meets international safety standards IEC61010-1 CAT III 300 V/CAT II 600 V. In addition, it has True RMS, 6040 counts with bar graph display, MIN/MAX, and REL (relative value) functions.
Features
DC V | |
Ranges | 600.0mV/6.000V/60.00V/600.0V/600V |
Measuring Range | 0 to 600V (5 Autoranging) |
Accuracy | 600.0mV/6.000V/60.00V/600.0V: ±0.5%rdg ±2dgt 600V: ±0.8%rdg ±3dgt |
AC V | |
Ranges | 6.000V/60.00V/600.0V/600V |
Measuring Range | 6.000V/60.00V/600.0V/600V: 0 to 600V (4 Autoranging) |
Accuracy | 6.000V: ±1.5%rdg ±5dgt at 50/60Hz; ±1.8%rdg ±5dgt at 40 to 400Hz 60.00V/600.0V: ±1.2%rdg ±3dgt at 50/60Hz; ±1.5%rdg ±3dgt at 40 to 400Hz 600V: ±1.5%rdg ±5dgt at 50/60Hz; ±1.8%rdg ±5dgt at 40 to 400Hz |
DC A | |
Ranges | 600.0µA/6000µA/60.00mA/600.00mA/6.000A/10.00A |
Measuring Range | 600.0µA/6000µA: 0 to 6000µA (2 Autoranging) 60.00mA/600.00mA: 0 to 600mA (2 Autoranging) 6.000A/10.00A: 0 to 10A (2 Autoranging) |
Accuracy | 600.0µA/6000µA/60.00mA/600.00mA: ±1.2%rdg ±3dgt 6.000A/10.00A: ±2.0%rdg ±5dgt |
AC A | |
Ranges | 600.0µA/6000µA/60.00mA/600.00mA/6.000A/10.00A |
Measuring Range | 600.0µA/6000µA: 0 to 6000µA (2 Autoranging) 60.00mA/600.00mA: 0 to 600mA (2 Autoranging) 6.000A/10.00A: 0 to 10A (2 Autoranging) |
Accuracy | 600.0µA/6000µA/60.00mA/600.00mA: ±1.5%rdg ±4dgt at 50/60Hz; ±2.0%rdg ±4dgt at 40 to 400Hz 6.000A/10.00A: ±2.2%rdg ±5dgt at 50/60Hz; ±2.5%rdg ±5dgt at 40 to 400Hz |
General Specifications | |
Frequency | 10/100/100Hz/10/100/1000kHz/10MHz |
Withstand Voltage | It should be more than AC3470V/ for 5 secs between electrical circuit and enclosures |
Power Source | 2 x R6P 1.5V Batteries |
Dimensions | 161 x 82 x 50 mm |
Weight | Approx. 280 g (Including Batteries) |
DC V | |
Ranges | 600.0mV/6.000V/60.00V/600.0V/600V |
Measuring Range | 0 to 600V (5 Autoranging) |
Accuracy | 600.0mV/6.000V/60.00V/600.0V: ±0.5%rdg ±2dgt 600V: ±0.8%rdg ±3dgt |
AC V | |
Ranges | 6.000V/60.00V/600.0V/600V |
Measuring Range | 6.000V/60.00V/600.0V/600V: 0 to 600V (4 Autoranging) |
Accuracy | 6.000V: ±1.5%rdg ±5dgt at 50/60Hz; ±1.8%rdg ±5dgt at 40 to 400Hz 60.00V/600.0V: ±1.2%rdg ±3dgt at 50/60Hz; ±1.5%rdg ±3dgt at 40 to 400Hz 600V: ±1.5%rdg ±5dgt at 50/60Hz; ±1.8%rdg ±5dgt at 40 to 400Hz |
DC A | |
Ranges | 600.0µA/6000µA/60.00mA/600.00mA/6.000A/10.00A |
Measuring Range | 600.0µA/6000µA: 0 to 6000µA (2 Autoranging) 60.00mA/600.00mA: 0 to 600mA (2 Autoranging) 6.000A/10.00A: 0 to 10A (2 Autoranging) |
Accuracy | 600.0µA/6000µA/60.00mA/600.00mA: ±1.2%rdg ±3dgt 6.000A/10.00A: ±2.0%rdg ±5dgt |
AC A | |
Ranges | 600.0µA/6000µA/60.00mA/600.00mA/6.000A/10.00A |
Measuring Range | 600.0µA/6000µA: 0 to 6000µA (2 Autoranging) 60.00mA/600.00mA: 0 to 600mA (2 Autoranging) 6.000A/10.00A: 0 to 10A (2 Autoranging) |
Accuracy | 600.0µA/6000µA/60.00mA/600.00mA: ±1.5%rdg ±4dgt at 50/60Hz; ±2.0%rdg ±4dgt at 40 to 400Hz 6.000A/10.00A: ±2.2%rdg ±5dgt at 50/60Hz; ±2.5%rdg ±5dgt at 40 to 400Hz |
General Specifications | |
Frequency | 10/100/100Hz/10/100/1000kHz/10MHz |
Withstand Voltage | It should be more than AC3470V/ for 5 secs between electrical circuit and enclosures |
Power Source | 2 x R6P 1.5V Batteries |
Dimensions | 161 x 82 x 50 mm |
Weight | Approx. 280 g (Including Batteries) |