Lightweight and user-friendly, this single-gas detector series features an easy-to-service single-gas detector with BLE connectivity. With real-time visibility into the status and safety of hazardous-area workers, these detectors help companies respond faster, more knowingly, and decisively to safety incidents.
Lightweight and user-friendly, this single-gas detector series features an easy-to-service single-gas detector with BLE connectivity. With real-time visibility into the status and safety of hazardous-area workers, these detectors help companies respond faster, more knowingly, and decisively to safety incidents.
This has high standards of sensor quality and reliability.
Features
To optimize safety, compliance and productivity, use the Solo with IntelliDoX docking stations and the Honeywell SafetySuite Device Configurator software.
IntelliDoX: automated testing, configuration and recordkeeping
Simply place the detector in the dock and it automatically transfers the test results and performs the actions you choose. You can do a bump test, change set points, enable calibration and/or bump reminders, update firmware and more. Fleet management software transfers the alarms, peak readings and other data to your computer via Ethernet or USB.
Want to bump one detector? Reconfigure another? Each dock in the group has its own crisp, easy-to-read LCD screen, keypad and pump for independent operation, while sharing power and calibration gas.
Device configurator: centralized compliance monitoring
With this Windows-based software, you can view and export detector data, configure alarm set points, deploy firmware updates and more. So you can improve safety, compliance and productivity.
One-button operation
The detector is easy to operate - even if you’re wearing gloves. Using this button or the Honeywell SafetySuite Device Configurator software, you can easily configure set points, latching alarms and other parameters. Also access measurements for short-term exposure limit (STEL), time-weighted average (TWA) and the highest concentration of gas detected in the past 24 hours.
Safety at a glance
Want to quickly determine whether a detector is in compliance? Just activate IntelliFlash™. This flashing green light - visible from a distance - means the detector has been bump tested and is monitoring correctly. Want to see when the detector is not in compliance? Activate the noncompliance flash, which blinks red when the detector needs a bump test, has detected a gas event, is due for calibration or needs a battery replaced. With this detector, you can choose the indicator that works for your operating procedures.
Alarms that are easy to see and hear
When the detector alarms, the LEDs around the detector illuminate red for high visibility. Additional vibrating and audible alarms ensure you’re aware of danger - even in noisy environments.
Assign detectors to workers and locations
If there’s a gas event, you can easily determine who used the detector and where.
Easy-to-read display for multiple languages
See real-time gas readings in your choice of English, Spanish, French, Korean, Japanese, Russian or other languages.
Data logging with rolling 24-hour peak reading
Want to see the highest gas level that a detector encountered? With this detector, you can see the peak gas reading in the past 24 hours, even if it didn’t trigger an alarm. So you have the visibility you need to correct small problems before they become bigger ones.
Humidity | 0 to 95% RH (non-condensing) |
Ingress Protection | IP66/68 |
Alarms and Type | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, non-compliance |
Self-Test | Sensor integrity, circuitry, battery and audible/visual alarms on activation; battery (continuous) |
Typical Battery Life | 12 months (6 months for 1-Series O2) |
Connected Worker | Bluetooth™ Low Energy (BLE) - Ability to connect to Honeywell's Safety Communicator App |
User Options | Reset TWA, STEL and Peak readings Change High, Low, TWA and STEL alarm set-points Latching alarms Enable IntelliFlash and non-compliance indicators Set calibration and/or bump test reminders Assign worker and location assignments Language select: English, French, Spanish, German, Italian, Russian, Japanese, Chinese, Korean, Portuguese, Dutch |
Certifications and Approvals | CSA, ATEX, IECEx, FCC ID, IC, RED |
Dimensions | 2.7 x 2.6 x 1.4" (7.0 x 6.7x 3.6 cm) (1-Series sensor models) 2.7 x 2.6 x 1.6" (7.0 x 6.7x 4.1 cm) (4-Series sensor models) |
Weight | 3.6 to 4.1 oz (103 to 116 g), depending on installed sensor |
Quick and precise management for your Honeywell gas detector fleet.
In your day-to-day work, you must ensure that workers comply with government regulation and corporate-issued safety policies. As part of this compliance, workers must have equipment that has been inspected for safety and training that certifies them to complete certain tasks.
Maybe you’re already spending too much time performing administration tasks. Your current system, call it repetitive, bulky, or tedious, can keep you from getting out of your office, developing safety policies, or otherwise collaborating with operations to improve your working environment.
Features
The Safety Suite Device Configurator software enables quick and precise management and maintenance of your Honeywell portable gas detector fleet.
As a Safety or Operations Manager, this is your tool of choice to simplify reporting and streamline administrative tasks. Its highly intuitive and user-friendly interface enables you to pull all the necessary data in an intelligent, effective, and timesaving way. Its state-of-the-art technology ensures that all the data is encrypted, minimizing privacy threats.
It’s an easy-to-use software solution to increase your productivity.
The Safety Suite Device Configurator enables you to manage your fleet of Honeywell portable gas detectors and docks with ease. It reduces the burden of administration and simplifies compliance so you can concentrate on keeping people safe.
Simple and intuitive user interface
Streamlined device management
Secure and flexible user management
Localized data
Hardware
CPU, 1.0 GHz or better
Color monitor (at least 1366 x 768 resolution, 16-bit color)
2 GB RAM
At least 4 GB of free hard disk space*
USB port for instrument/dock station connection
LAN connection for network-connected dock stations
Optional Internet connection (to access Product Registration Module)
*Software installation only. Safety Suite Device Configurator may require significantly larger amounts of disk space to store device data and other software data.
Software
Windows® 7 32-bit SP1; Windows 7 64-bit SP1; Windows 10 64-bit
Microsoft® .NET Framework V4.6.1 or above (can be installed with Honeywell Safety Suite Device Configurator installation)
User privilege
During installation, you must have administrator privileges on the local PC.
Note: Administrator privileges are not required in order to run the program from desktop.
Easy data transfer
By Ethernet or USB - from docking module to computer. Refer to individual docks for specification.
Humidity | 0 to 95% RH (non-condensing) |
Ingress Protection | IP66/68 |
Alarms and Type | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, non-compliance |
Self-Test | Sensor integrity, circuitry, battery and audible/visual alarms on activation; battery (continuous) |
Typical Battery Life | 12 months (6 months for 1-Series O2) |
Connected Worker | Bluetooth™ Low Energy (BLE) - Ability to connect to Honeywell's Safety Communicator App |
User Options | Reset TWA, STEL and Peak readings Change High, Low, TWA and STEL alarm set-points Latching alarms Enable IntelliFlash and non-compliance indicators Set calibration and/or bump test reminders Assign worker and location assignments Language select: English, French, Spanish, German, Italian, Russian, Japanese, Chinese, Korean, Portuguese, Dutch |
Certifications and Approvals | CSA, ATEX, IECEx, FCC ID, IC, RED |
Dimensions | 2.7 x 2.6 x 1.4" (7.0 x 6.7x 3.6 cm) (1-Series sensor models) 2.7 x 2.6 x 1.6" (7.0 x 6.7x 4.1 cm) (4-Series sensor models) |
Weight | 3.6 to 4.1 oz (103 to 116 g), depending on installed sensor |
Quick and precise management for your Honeywell gas detector fleet.
In your day-to-day work, you must ensure that workers comply with government regulation and corporate-issued safety policies. As part of this compliance, workers must have equipment that has been inspected for safety and training that certifies them to complete certain tasks.
Maybe you’re already spending too much time performing administration tasks. Your current system, call it repetitive, bulky, or tedious, can keep you from getting out of your office, developing safety policies, or otherwise collaborating with operations to improve your working environment.
Features
The Safety Suite Device Configurator software enables quick and precise management and maintenance of your Honeywell portable gas detector fleet.
As a Safety or Operations Manager, this is your tool of choice to simplify reporting and streamline administrative tasks. Its highly intuitive and user-friendly interface enables you to pull all the necessary data in an intelligent, effective, and timesaving way. Its state-of-the-art technology ensures that all the data is encrypted, minimizing privacy threats.
It’s an easy-to-use software solution to increase your productivity.
The Safety Suite Device Configurator enables you to manage your fleet of Honeywell portable gas detectors and docks with ease. It reduces the burden of administration and simplifies compliance so you can concentrate on keeping people safe.
Simple and intuitive user interface
Streamlined device management
Secure and flexible user management
Localized data
Hardware
CPU, 1.0 GHz or better
Color monitor (at least 1366 x 768 resolution, 16-bit color)
2 GB RAM
At least 4 GB of free hard disk space*
USB port for instrument/dock station connection
LAN connection for network-connected dock stations
Optional Internet connection (to access Product Registration Module)
*Software installation only. Safety Suite Device Configurator may require significantly larger amounts of disk space to store device data and other software data.
Software
Windows® 7 32-bit SP1; Windows 7 64-bit SP1; Windows 10 64-bit
Microsoft® .NET Framework V4.6.1 or above (can be installed with Honeywell Safety Suite Device Configurator installation)
User privilege
During installation, you must have administrator privileges on the local PC.
Note: Administrator privileges are not required in order to run the program from desktop.
Easy data transfer
By Ethernet or USB - from docking module to computer. Refer to individual docks for specification.