Portable and compact, this power logger accurately and safely measures single to three-phase lines and 4-cut wires for energy audits and energy conservation. Moreover, this logger kit includes clamp-on sensors, a power logger viewer, a voltage cord, an AC adapter, a rechargeable battery pack, a hard case, and many more.
Portable and compact, this power logger accurately and safely measures single to three-phase lines and 4-cut wires for energy audits and energy conservation. Moreover, this logger kit includes clamp-on sensors, a power logger viewer, a voltage cord, an AC adapter, a rechargeable battery pack, a hard case, and many more.
Accepting both clamp and pulse inputs, this Clamp-on power logger kit can monitor multiple variables at once. It comes with everything you need to start collecting power data, like multicolored clips, spiral tubes, clamp-on sensors, a power logger viewer and even more. Plus, you can store months of data on the accompanying 2 GB SD memory card for later viewing and analysis. Measures power on both single and 3-phase lines.
Features
Applications
Measurement | Voltage, current, power, demand |
Harmonic Analysis | Not included with this model |
Load Current | 15/10/50/100 A (with clamp-on sensor 9660) |
Measurement Line Type | Single-phase 2 or 3 wire; 3-phase 3 or 4 wire |
Measurement Line Frequency | 50/60 Hz |
Input | Voltage (3 channels), current (3 channels) |
Voltage | 90 to 780 V; 600 V AC |
Communication | LAN, USB 2.0 |
Pulse Input | No-voltage contact input (counts when shorted terminals open): HI: 2 to 45 V LO: 0 to 0.5 V |
Pulse Measurement Range | 0 to 9999 |
Pulse Output | Open collector 30 V, 5 mA (maximum) |
Display | 3.5" (8.89 cm) color LCD |
Memory Storage | 2 GB SD card (included) |
Power Supply | AC adapter Z1006 (12 V, 1.25 A): 100 to 240 VAC, 50/60 Hz, 40 VA (including AC adapter) |
Compliance | CE, EN61010, EN61326, EN61000-3-2, EN61000-3-3 |
Dimensions | Power logger: 1.89 x 7.09 x 3.94" (48 x 180 x 100 mm) Cord: 9.84' (3 m) |
Weight | 1.2 lbs (550 g) without battery pack 1.8 lbs (830 g) with battery pack |
Measurement | Voltage, current, power, demand |
Harmonic Analysis | Not included with this model |
Load Current | 15/10/50/100 A (with clamp-on sensor 9660) |
Measurement Line Type | Single-phase 2 or 3 wire; 3-phase 3 or 4 wire |
Measurement Line Frequency | 50/60 Hz |
Input | Voltage (3 channels), current (3 channels) |
Voltage | 90 to 780 V; 600 V AC |
Communication | LAN, USB 2.0 |
Pulse Input | No-voltage contact input (counts when shorted terminals open): HI: 2 to 45 V LO: 0 to 0.5 V |
Pulse Measurement Range | 0 to 9999 |
Pulse Output | Open collector 30 V, 5 mA (maximum) |
Display | 3.5" (8.89 cm) color LCD |
Memory Storage | 2 GB SD card (included) |
Power Supply | AC adapter Z1006 (12 V, 1.25 A): 100 to 240 VAC, 50/60 Hz, 40 VA (including AC adapter) |
Compliance | CE, EN61010, EN61326, EN61000-3-2, EN61000-3-3 |
Dimensions | Power logger: 1.89 x 7.09 x 3.94" (48 x 180 x 100 mm) Cord: 9.84' (3 m) |
Weight | 1.2 lbs (550 g) without battery pack 1.8 lbs (830 g) with battery pack |