FREE SHIPPING ON ONLINE ORDERS OVER $99*

Hioki CM4141-50 True RMS AC Clamp Meter, 2000 A AC

Model: CM4141-50

Hioki CM4141-50 True RMS AC Clamp Meter, 2000 A AC

Model: CM4141-50

Features a uniquely designed slim jaw to easily get into the narrow gaps between cables in crowded electrical distribution boxes. Offers a current measurement range of 2000 A AC, along with a broad operating temperature range of -13 to 149°F (-25 to 65°C) and IP50 dustproof and waterproof enclosure. W/ Wireless Adapter.

Features a uniquely designed slim jaw to easily get into the narrow gaps between cables in crowded electrical distribution boxes. Offers a current measurement range of 2000 A AC, along with a broad operating temperature range of -13 to 149°F (-25 to 65°C) and IP50 dustproof and waterproof enclosure. W/ Wireless Adapter.

Your Price $299.00 USD
Availability 3 to 4 Weeks
Quantity

Traceable In-House Calibration Certificate for your Hioki CM4141-50 True RMS AC Clamp Meter

Traceable In-House Calibration Certificate for your Hioki CM4141-50 True RMS AC Clamp Meter

Hioki CM4142 Offers

Innovative Current Sensor Design, Easily Get Into Tight Spaces

A True RMS clamp meter that features a broad operating temperature range of -13 to 149°F (-25 to 65°C) and IP50 dustproof and waterproof enclosure to enable professionals to work quickly in crowded electrical distribution panels.

Features

  • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 0.43" (11 mm)
  • Measure up to 2000 A AC
  • AC A, AC and DC V, DC+AC V, resistance, frequency, temperature, and more
  • Expanded -13 to 149°F (-25 to 65°C) operating temperature range
  • Rating of CAT IV 600 V and CAT III 1000 V

Applications

  • Industrial

Download the App

Hioki CM4141-50 Specifications

Current Measurement 2000 A AC maximum
AC Current Range 60.00 to 2000 A
3 ranges (45 Hz to 1 kHz, True RMS)
Basic accuracy 45 to 66 Hz: ±1.5% rdg. ±0.08 A
Crest Factor For the 60.00 A range (50.00 A or less), 3
For the 60.00 A range (greater than 50.00 A and less than or equal to 60.00 A), 2.5
For the 600.0 A range (500.0 A or less), 3
For the 600.0 A range (greater than 500.0 A and less than or equal to 600.0 A), 2.5
For the 2000 A range (2000 A or less), 1.5
DC Voltage Range 600.0 mV to 1500 V
5 ranges
Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
AC Voltage Range 6.000 to 1000 V
4 ranges (15 Hz to 1 kHz, True RMS)
Basic accuracy: 45 to 66 Hz: ±0.9% rdg. 0.003 V (at 6 V)
DC+AC Voltage Range 6.000 to 1000 V
4 ranges
Basic accuracy DC: 45 to 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance Range 600.0 Ω to 600.0 kΩ
4 ranges
Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic Capacity Range 1.000 to 1000 μF
4 ranges
Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency Range Voltage: 9.999 to 999.9 Hz, 3 ranges
Current: 99.99 to 999.9 Hz, 2 ranges
Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz)
Temperature (K) -40 to 752°F (-40 to 400°C)
Basic accuracy: ±0.5% rdg. ±3.0°C + temperature probe accuracy
Rating IP50
Power Supply 2 x Alkaline batteries
Continuous Use Approx. 24 hours (Backlight OFF, Bluetooth® ON)
Approx. 48 hours (Backlight OFF, Bluetooth® OFF)
Core Jaw 3.23 x 0.43" (82 x 11 mm), diameter of Ø2.17" (55 mm)
Dimensions 2.56 x 9.72 x 1.38" (65 x 247 x 35 mm)
Click here for complete specifications on the Hioki CM4141-50

What's included with the Hioki CM4141-50

  • Clamp Meter
  • Test Lead
  • Carrying Case
  • 2 x LR03 Alkaline Batteries
  • Instruction Manual
  • Usage Notes

Click on a category to view a selection of compatible accessories with the Hioki CM4141-50 True RMS AC Clamp Meter, 2000 A AC.

Hioki 9243 Red/Black Grabber Clip Set, 1,000V 9243
These grabber clips easily attach to your banana plug cables and are capable of handling up to 1,000V. The clips measure 7.72in (196mm) long.




Hioki L4936 Bus Bar Clip Set, 600V L4936
This bus bar clip set attaches to the tips of the banana plug cables for your compatible digital multimeter. The clips are capable of handling up to 600V.




Hioki Carrying Case C0204
For use with the CM4000 series.




Hioki L4939 Breaker Pin Set, 600V L4939
Attach these breaker pins to your compatible test lead cables to take measurements. The pins easily attach to banana plugs.




Hioki L4938 Digital Multimeter Test Pin Set, Cat III 600V L4938
Test electrical systems using your compatible meter and this set of test pins. They work with select Hioki digital multimeters.




Hioki L4933 Contact Pin Set, 70VDC/33VAC, Black/Red L4933
Attach these contact pins to your compatible test leads to take precise measurements. The pins are capable of handling 70VDC and 33VAC signals.




Hioki L4932 Digital Multimeter Test Pin Set, Cat IV 600V/Cat III 1,000V L4932
Test electrical systems using your compatible meter and this set of test pins. They work with select Hioki digital multimeters.




Hioki L4937 Magnetic Adapter Set, 1,000V L4937
You can easily attach these adapters to your banana plug cords. The adapters feature magnetic attachment for simple setup.




Hioki 9804 Magnetic Adapter Set, Black/Red 9804
These adapters attach to the tips of your compatible device's cords magnetically. The colors makes them easy to identify on the job.




Hioki L4935 Alligator Clip Set, 600/1,000V L4935
With this clip set, you can easily connect to your compatible digital multimeter. The clips feature an alligator design for simple attachment.




Hioki L4934 Alligator Clip Set, Small L4934
Attach this alligator clip set to the leads on your compatible units. This clip set works with Hioki models L4932, L9207-10/DT4911, L9206, CAT III 300V and CAT II 600V.




Hioki L4931 Extension Cable Set, 4.92ft L4931
Use these cables to extend the length of your existing ones. The cables feature banana plugs for easy connectivity.




Hioki L4930 Connection Cable Set, 3.94ft L4930
Use this cable set with your compatible Hioki digital multimeter. The cables measure 3.94ft (1.2m) long for a comfortable reach.




Hioki L9207-10 Test Lead for the CM4000 and DT4200 Series L9207-10
For use with CM4000 Clamp Meters and DT4200 Digital Multimeters.




Ask a question about Hioki CM4141-50 True RMS AC Clamp Meter, 2000 A AC

Customer Reviews for the Hioki CM4141-50

Hioki CM4142 Offers

Innovative Current Sensor Design, Easily Get Into Tight Spaces

A True RMS clamp meter that features a broad operating temperature range of -13 to 149°F (-25 to 65°C) and IP50 dustproof and waterproof enclosure to enable professionals to work quickly in crowded electrical distribution panels.

Features

  • Easily get into tight spaces between cables thanks to thin sensor with a minimum cross-section span of 0.43" (11 mm)
  • Measure up to 2000 A AC
  • AC A, AC and DC V, DC+AC V, resistance, frequency, temperature, and more
  • Expanded -13 to 149°F (-25 to 65°C) operating temperature range
  • Rating of CAT IV 600 V and CAT III 1000 V

Applications

  • Industrial

Download the App

Hioki CM4141-50 Specifications

Current Measurement 2000 A AC maximum
AC Current Range 60.00 to 2000 A
3 ranges (45 Hz to 1 kHz, True RMS)
Basic accuracy 45 to 66 Hz: ±1.5% rdg. ±0.08 A
Crest Factor For the 60.00 A range (50.00 A or less), 3
For the 60.00 A range (greater than 50.00 A and less than or equal to 60.00 A), 2.5
For the 600.0 A range (500.0 A or less), 3
For the 600.0 A range (greater than 500.0 A and less than or equal to 600.0 A), 2.5
For the 2000 A range (2000 A or less), 1.5
DC Voltage Range 600.0 mV to 1500 V
5 ranges
Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
AC Voltage Range 6.000 to 1000 V
4 ranges (15 Hz to 1 kHz, True RMS)
Basic accuracy: 45 to 66 Hz: ±0.9% rdg. 0.003 V (at 6 V)
DC+AC Voltage Range 6.000 to 1000 V
4 ranges
Basic accuracy DC: 45 to 66 Hz: ±1.0% rdg. ±0.013 V (at 6 V)
Resistance Range 600.0 Ω to 600.0 kΩ
4 ranges
Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic Capacity Range 1.000 to 1000 μF
4 ranges
Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency Range Voltage: 9.999 to 999.9 Hz, 3 ranges
Current: 99.99 to 999.9 Hz, 2 ranges
Basic accuracy: ±0.1% rdg. ±0.01 Hz (at 99.99 Hz)
Temperature (K) -40 to 752°F (-40 to 400°C)
Basic accuracy: ±0.5% rdg. ±3.0°C + temperature probe accuracy
Rating IP50
Power Supply 2 x Alkaline batteries
Continuous Use Approx. 24 hours (Backlight OFF, Bluetooth® ON)
Approx. 48 hours (Backlight OFF, Bluetooth® OFF)
Core Jaw 3.23 x 0.43" (82 x 11 mm), diameter of Ø2.17" (55 mm)
Dimensions 2.56 x 9.72 x 1.38" (65 x 247 x 35 mm)
Click here for complete specifications on the Hioki CM4141-50

What's included with the Hioki CM4141-50

  • Clamp Meter
  • Test Lead
  • Carrying Case
  • 2 x LR03 Alkaline Batteries
  • Instruction Manual
  • Usage Notes

Click on a category to view a selection of compatible accessories with the Hioki CM4141-50 True RMS AC Clamp Meter, 2000 A AC.

Hioki 9243 Red/Black Grabber Clip Set, 1,000V 9243
These grabber clips easily attach to your banana plug cables and are capable of handling up to 1,000V. The clips measure 7.72in (196mm) long.




Hioki L4936 Bus Bar Clip Set, 600V L4936
This bus bar clip set attaches to the tips of the banana plug cables for your compatible digital multimeter. The clips are capable of handling up to 600V.




Hioki Carrying Case C0204
For use with the CM4000 series.




Hioki L4939 Breaker Pin Set, 600V L4939
Attach these breaker pins to your compatible test lead cables to take measurements. The pins easily attach to banana plugs.




Hioki L4938 Digital Multimeter Test Pin Set, Cat III 600V L4938
Test electrical systems using your compatible meter and this set of test pins. They work with select Hioki digital multimeters.




Hioki L4933 Contact Pin Set, 70VDC/33VAC, Black/Red L4933
Attach these contact pins to your compatible test leads to take precise measurements. The pins are capable of handling 70VDC and 33VAC signals.




Hioki L4932 Digital Multimeter Test Pin Set, Cat IV 600V/Cat III 1,000V L4932
Test electrical systems using your compatible meter and this set of test pins. They work with select Hioki digital multimeters.




Hioki L4937 Magnetic Adapter Set, 1,000V L4937
You can easily attach these adapters to your banana plug cords. The adapters feature magnetic attachment for simple setup.




Hioki 9804 Magnetic Adapter Set, Black/Red 9804
These adapters attach to the tips of your compatible device's cords magnetically. The colors makes them easy to identify on the job.




Hioki L4935 Alligator Clip Set, 600/1,000V L4935
With this clip set, you can easily connect to your compatible digital multimeter. The clips feature an alligator design for simple attachment.




Hioki L4934 Alligator Clip Set, Small L4934
Attach this alligator clip set to the leads on your compatible units. This clip set works with Hioki models L4932, L9207-10/DT4911, L9206, CAT III 300V and CAT II 600V.




Hioki L4931 Extension Cable Set, 4.92ft L4931
Use these cables to extend the length of your existing ones. The cables feature banana plugs for easy connectivity.




Hioki L4930 Connection Cable Set, 3.94ft L4930
Use this cable set with your compatible Hioki digital multimeter. The cables measure 3.94ft (1.2m) long for a comfortable reach.




Hioki L9207-10 Test Lead for the CM4000 and DT4200 Series L9207-10
For use with CM4000 Clamp Meters and DT4200 Digital Multimeters.




Ask a question about Hioki CM4141-50 True RMS AC Clamp Meter, 2000 A AC

Customer Reviews for the Hioki CM4141-50

More Hioki Products

Calibration Lab