This full-immersion PRT has lead wires made of single-conductor enameled copper, which prevents moisture from wicking to the sensing element.
This full-immersion PRT has lead wires made of single-conductor enameled copper, which prevents moisture from wicking to the sensing element.
This full-immersion PRT has a calibration accuracy of ±0.05°C.
Features
Temperature Range | -328 to 320°F (-200 to 160°C) |
Nominal Resistance At 0.01°C | 100Ω ±0.1Ω |
Temperature Coefficient | 0.00385Ω/Ω/°C |
Accuracy | ±0.04 at 0.01°C; ±0.06 at 160°C |
Short-Term Repeatability | ±0.03 at 0.01°C; ±0.04 at 160°C |
Drift | ±0.03 at 0.01°C; ±0.04 at 160°C |
Hysteresis | ±0.015°C |
Sheath Length | 1.97in ±0.2in (50mm ±5mm) |
Sheath Diameter | 0.13in ±0.004in (3.1mm ±0.1mm) |
Sheath Material | 316 SST |
Transition Junction Temperature Range | -328 to 320°F (-200 to 160°C) |
Sensor Length | 1.2in ±0.1 in (30mm ±3mm) |
Sensor Location | 1.2in ±0.04in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 20MΩ at 23°C |
Minimum Immersion Length | Full immersion |
Maximum Immersion Depth In Liquid Medium | Full immersion |
Maximum Immersion Depth In Dry Medium | Full immersion |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | ±0.003°C |
Lead-Wire Cable Type | Enameled copper wire |
Lead-Wire Length | 8ft (2.4m) |
Lead-Wire Temperature Range | 320°F (160°C) |
Calibration | Calibration not included. NVLAP accredited calibration available. See ordering information |
Click on a category to view a selection of compatible accessories with the Fluke 5606-50-A Full-Immersion PRT with INFO-CON for 914X.
Temperature Range | -328 to 320°F (-200 to 160°C) |
Nominal Resistance At 0.01°C | 100Ω ±0.1Ω |
Temperature Coefficient | 0.00385Ω/Ω/°C |
Accuracy | ±0.04 at 0.01°C; ±0.06 at 160°C |
Short-Term Repeatability | ±0.03 at 0.01°C; ±0.04 at 160°C |
Drift | ±0.03 at 0.01°C; ±0.04 at 160°C |
Hysteresis | ±0.015°C |
Sheath Length | 1.97in ±0.2in (50mm ±5mm) |
Sheath Diameter | 0.13in ±0.004in (3.1mm ±0.1mm) |
Sheath Material | 316 SST |
Transition Junction Temperature Range | -328 to 320°F (-200 to 160°C) |
Sensor Length | 1.2in ±0.1 in (30mm ±3mm) |
Sensor Location | 1.2in ±0.04in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 20MΩ at 23°C |
Minimum Immersion Length | Full immersion |
Maximum Immersion Depth In Liquid Medium | Full immersion |
Maximum Immersion Depth In Dry Medium | Full immersion |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | ±0.003°C |
Lead-Wire Cable Type | Enameled copper wire |
Lead-Wire Length | 8ft (2.4m) |
Lead-Wire Temperature Range | 320°F (160°C) |
Calibration | Calibration not included. NVLAP accredited calibration available. See ordering information |