Measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. This value-added kit includes the REED CA-05A Soft Carrying Case and the REED R5110 Non-Contact Voltage Detector for FREE.
Measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. This value-added kit includes the REED CA-05A Soft Carrying Case and the REED R5110 Non-Contact Voltage Detector for FREE.
Features
Applications
REED CA-05A Medium Soft Carrying Case
Features
REED R5110 Non-Contact Voltage Detector with Flashlight
This Voltage Detector has the ability to detect the presence of AC voltage from a safe distance. The R5110 features two voltage ranges allowing it to detect both high (90 to 1000V) and low (24 to 1000V) AC voltage wiring.
Features
Temperature Accuracy | |
Above -100°C | J, K, T, and E-type: ±[0.05% + 0.3°C] |
Below -100°C | J, K, and E: ±[0.20% + 0.3°C] |
Temperature | |
J-Type | -346 to 2192°F (-210 to 1200°C) |
K-Type | -328 to 2501.6°F (-200 to 1372°C) |
T-Type | -418 to 752°F (-250 to 400°C) |
E-Type | -238 to 1832°F (-150 to 1000°C) |
Temperature Scale | ITS-90 |
Applicable Standards | NIST-175 |
Display Resolution | 0.1°C, 0.1 K <1000 1°C, 1 K ≥1000 |
Environmental Specifications | |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Humidity (Without Condensation) | 0 to 90%; 32 to 95°F (0 to 35°C) 0 to 70%; 32 to 122°F (0 to 50°C) |
Mechanical and General Specifications | |
Batteries | 3 x batteries Typical 1000-hour life |
Dimensions | 6.8 x 3.4 x 1.5" (173 x 86 x 38 mm) |
Weight | 0.9 lbs (400 g) |
Safety Specifications | |
Overvoltage Category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
Agency Approvals | CE, CSA, TÜV (pending) |
Relative time clock on MIN, MAX, and AVG provides a time reference for major events. Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy.
Outside Dimensions (LxWxH): 9x 4 x 2" (228 x 102 x 51mm), Black polyester.
AC Voltage Detector with built-in flashlight and pocket clip.
Click on a category to view a selection of compatible accessories with the Fluke 51-2 Single Input Thermometer Kit - Includes FREE Products with Purchase.
Temperature Accuracy | |
Above -100°C | J, K, T, and E-type: ±[0.05% + 0.3°C] |
Below -100°C | J, K, and E: ±[0.20% + 0.3°C] |
Temperature | |
J-Type | -346 to 2192°F (-210 to 1200°C) |
K-Type | -328 to 2501.6°F (-200 to 1372°C) |
T-Type | -418 to 752°F (-250 to 400°C) |
E-Type | -238 to 1832°F (-150 to 1000°C) |
Temperature Scale | ITS-90 |
Applicable Standards | NIST-175 |
Display Resolution | 0.1°C, 0.1 K <1000 1°C, 1 K ≥1000 |
Environmental Specifications | |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Humidity (Without Condensation) | 0 to 90%; 32 to 95°F (0 to 35°C) 0 to 70%; 32 to 122°F (0 to 50°C) |
Mechanical and General Specifications | |
Batteries | 3 x batteries Typical 1000-hour life |
Dimensions | 6.8 x 3.4 x 1.5" (173 x 86 x 38 mm) |
Weight | 0.9 lbs (400 g) |
Safety Specifications | |
Overvoltage Category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
Agency Approvals | CE, CSA, TÜV (pending) |
Relative time clock on MIN, MAX, and AVG provides a time reference for major events. Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy.
Outside Dimensions (LxWxH): 9x 4 x 2" (228 x 102 x 51mm), Black polyester.
AC Voltage Detector with built-in flashlight and pocket clip.
Click on a category to view a selection of compatible accessories with the Fluke 51-2 Single Input Thermometer Kit - Includes FREE Products with Purchase.