AMETEK Crystal nVision Series Reference Recorder

AMETEK Crystal nVision Series Reference Recorder

Differential pressure with up to 0.025% of reading accuracy, there's never been anything like this reference recorder. Rugged enough to sit in 3' of water, this reference recorder can perform calibrations anytime, anywhere. Carrying case not included with "no pump" option.

Differential pressure with up to 0.025% of reading accuracy, there's never been anything like this reference recorder. Rugged enough to sit in 3' of water, this reference recorder can perform calibrations anytime, anywhere. Carrying case not included with "no pump" option.

Configure This Product:

nVision Base
Upper Module
Lower Module
Pump Systems
Pump Case Option
Baro Module
To view your pricing & availability, choose your options and add this item to your cart.
Ordering Number
Differential pressure with up to 0.025% of reading accuracy, there's never been anything like this reference recorder. Rugged enough to sit in 3' of water, this reference recorder can perform calibrations anytime, anywhere. Carrying case not included with "no pump" option.
Your Price $
Availability
Quantity

Crystal Pressure nVision Series Offers

Accurate enough to replace a deadweight tester, this reference recorder has a rugged build and can sit in up to 3' of water and is portable to complete calibrations anytime and anywhere.

Features

  • Gauge/absolute pressure datalogger to 15,000 psi/1000 bar/100 MPa
  • Differential pressure with up to 0.025% of reading accuracy
  • Shows switch, voltage, current, and temperature
  • 500,000 data points - 10 readings per second from 2 modules
  • Shift everyday wear to replaceable CPF adapter
  • Displays live data graphically - no PC required
  • Connects to a PC to view live readings or export to tamper proof digital records
  • Compensates accuracy for temperature effects from -20 to 50°C

Crystal Pressure nVision Series Specifications

Accuracy - psi (Gauge Pressure)
30, 100, and 300 psi modules 0 to 30% of Range: ±(0.0075% of full scale)
30 to 110%: ±(0.025% of reading)
Vacuum for 30 and 100 psi: ±(0.06% of Full Scale)
Vacuum for 300 psi: ±(0.06% of full scale) ±1 LSD
1000, 3000, 10,000, and 15,000 psi modules 0 to 30% of range: ±(0.015% of full scale)
30 to 110% of range: ±(0.05% of reading)
Accuracy - psiA (Pressure with BARO Module)
30 psi Module 0.2 to 14.5 psiA: ±0.011 psiA
14.5 to 44.5 psiA: ±(0.025% of reading) + 0.003 psiA
100 psi Module 0.2 to 14.5 psiA: ±0.011 psiA
14.5 to 44.5 psiA: ±0.011 psiA
44.5 to 114.5 psiA: ±(0.025% of reading)
300 psi Module 0.2 to 14.5 psiA: ±0.01 psiA
14.5 to 104.5 psiA: ±0.03 psiA
104.5 to 314.5 psiA: ±(0.025% of reading)
1000 psi Module 14.5 to 314.5 psiA: ±0.2 psiA
314.5 to 1014.5 psiA: ±(0.05% of reading)
3000 psi Module 14.5 to 914.5 psiA: ±0.5 psiA
914.5 to 3014.5 psiA: ±(0.05% of reading)
10,000 psi Module 15 to 3015 psiA: ±2 psiA
3015 to 10,015 psiA: ±(0.05% of reading)
15,000 psi Module 15 to 4515 psiA: ±3 psiA
4515 to 15,015 psiA: ±(0.05% of reading)
Current (mA) Input
Accuracy ±(0.015% of rdg + 0.002 mA)
Range 0 to 55 mA (MA20)
Maximum Allowable Current 93.3 mA
Resolution 0.001 mA or 0.01%
Units mA, % 4-20, % 10-50
Input Resistance <17.2 Ω
Voltage Burden at 20 mA 20 mA: <0.35 V
50 mA: <0.86 V
HART Resistance 250 Ω
Connection 2 mm jacks
Voltage (V DC) Input
Accuracy ±(0.015 % of rdg + 0.002 V DC)
Range 0 to 28 V DC
Max Allowable Voltage 30 V DC
Resolution 0.001 V DC
Units V DC
Switch Test
Switch Type Dry contact
Closed State Resistance <10 Ω
Open State Resistance >10 MΩ
General Specifications
Datalogging Capacity: Approximately 1,000,000 data points
Storage type: Non-volatile flash memory
Fastest interval: 10 per second
Slowest interval: 1 per hour
Temperature Operating: -4 to 122°F (-20 to 50°C)
Storage: -40 to 167°F (-40 to 75°C)
Data and Communication Digital interface: mini-USB
Display 255 x 160 pixel graphical display
Display Rate 4 readings/second (standard) up to 10 readings/second (recording)
Power 4 x AA: 200 hours, typical
Ultra low power: up to 60 days, typical
Housing Impact resistant injection molded
Keypads and Labels UV resistant polyester
Mounting M4 x 0.7 [0.31" [8 mm]) deep threaded insert mounting location
Rating IP66 and IP67
Weight 1.5 lbs (680 g)
Rating IP66 and IP67
Click here for complete specifications on the Crystal Pressure nVision Series

What's included with the Crystal Pressure nVision Series

  • Reference Recorder
  • Certificate of Calibration

Ask a question about AMETEK Crystal nVision Series Reference Recorder

Customer Reviews for the Crystal Pressure nVision Series

Crystal Pressure nVision Series Offers

Accurate enough to replace a deadweight tester, this reference recorder has a rugged build and can sit in up to 3' of water and is portable to complete calibrations anytime and anywhere.

Features

  • Gauge/absolute pressure datalogger to 15,000 psi/1000 bar/100 MPa
  • Differential pressure with up to 0.025% of reading accuracy
  • Shows switch, voltage, current, and temperature
  • 500,000 data points - 10 readings per second from 2 modules
  • Shift everyday wear to replaceable CPF adapter
  • Displays live data graphically - no PC required
  • Connects to a PC to view live readings or export to tamper proof digital records
  • Compensates accuracy for temperature effects from -20 to 50°C

Crystal Pressure nVision Series Specifications

Accuracy - psi (Gauge Pressure)
30, 100, and 300 psi modules 0 to 30% of Range: ±(0.0075% of full scale)
30 to 110%: ±(0.025% of reading)
Vacuum for 30 and 100 psi: ±(0.06% of Full Scale)
Vacuum for 300 psi: ±(0.06% of full scale) ±1 LSD
1000, 3000, 10,000, and 15,000 psi modules 0 to 30% of range: ±(0.015% of full scale)
30 to 110% of range: ±(0.05% of reading)
Accuracy - psiA (Pressure with BARO Module)
30 psi Module 0.2 to 14.5 psiA: ±0.011 psiA
14.5 to 44.5 psiA: ±(0.025% of reading) + 0.003 psiA
100 psi Module 0.2 to 14.5 psiA: ±0.011 psiA
14.5 to 44.5 psiA: ±0.011 psiA
44.5 to 114.5 psiA: ±(0.025% of reading)
300 psi Module 0.2 to 14.5 psiA: ±0.01 psiA
14.5 to 104.5 psiA: ±0.03 psiA
104.5 to 314.5 psiA: ±(0.025% of reading)
1000 psi Module 14.5 to 314.5 psiA: ±0.2 psiA
314.5 to 1014.5 psiA: ±(0.05% of reading)
3000 psi Module 14.5 to 914.5 psiA: ±0.5 psiA
914.5 to 3014.5 psiA: ±(0.05% of reading)
10,000 psi Module 15 to 3015 psiA: ±2 psiA
3015 to 10,015 psiA: ±(0.05% of reading)
15,000 psi Module 15 to 4515 psiA: ±3 psiA
4515 to 15,015 psiA: ±(0.05% of reading)
Current (mA) Input
Accuracy ±(0.015% of rdg + 0.002 mA)
Range 0 to 55 mA (MA20)
Maximum Allowable Current 93.3 mA
Resolution 0.001 mA or 0.01%
Units mA, % 4-20, % 10-50
Input Resistance <17.2 Ω
Voltage Burden at 20 mA 20 mA: <0.35 V
50 mA: <0.86 V
HART Resistance 250 Ω
Connection 2 mm jacks
Voltage (V DC) Input
Accuracy ±(0.015 % of rdg + 0.002 V DC)
Range 0 to 28 V DC
Max Allowable Voltage 30 V DC
Resolution 0.001 V DC
Units V DC
Switch Test
Switch Type Dry contact
Closed State Resistance <10 Ω
Open State Resistance >10 MΩ
General Specifications
Datalogging Capacity: Approximately 1,000,000 data points
Storage type: Non-volatile flash memory
Fastest interval: 10 per second
Slowest interval: 1 per hour
Temperature Operating: -4 to 122°F (-20 to 50°C)
Storage: -40 to 167°F (-40 to 75°C)
Data and Communication Digital interface: mini-USB
Display 255 x 160 pixel graphical display
Display Rate 4 readings/second (standard) up to 10 readings/second (recording)
Power 4 x AA: 200 hours, typical
Ultra low power: up to 60 days, typical
Housing Impact resistant injection molded
Keypads and Labels UV resistant polyester
Mounting M4 x 0.7 [0.31" [8 mm]) deep threaded insert mounting location
Rating IP66 and IP67
Weight 1.5 lbs (680 g)
Rating IP66 and IP67
Click here for complete specifications on the Crystal Pressure nVision Series

What's included with the Crystal Pressure nVision Series

  • Reference Recorder
  • Certificate of Calibration

Ask a question about AMETEK Crystal nVision Series Reference Recorder

Customer Reviews for the Crystal Pressure nVision Series

More Crystal Pressure Products

Calibration Lab