The humidity data logger takes both temperature and relative humidity readings in one compact size unit. It features a USB interface and a memory size selection of 1000, 2000, 4000, 8000, 12,000, or 16,000 data points.
The humidity data logger takes both temperature and relative humidity readings in one compact size unit. It features a USB interface and a memory size selection of 1000, 2000, 4000, 8000, 12,000, or 16,000 data points.
Features:
Display | 3¾ digit liquid crystal display (LCD) with a maximum reading of 1999 |
Sampling points | 1 K / 2 K / 4 K / 8 K / 12 K / 16 K |
Resolution | Temperature 0.1°C / 0.1°F RH Resolution 0.1% |
LED | Red: Hi, LO Alarm Yellow: Record |
Low Battery Indication | The "Batt" is displayed when the battery voltage drops below the operating level |
Auto Power Off | Approximately 10 minutes |
Operating Environment | 14 to 140°F (-10 to 60°C), 0 to 100% RH |
Storage Temperature | -40 to 185°F (-40 to 85°C), 0 to 100% RH |
Measurement Ranges | Temperature Internal sensor -40 to 185°F (-40 to 85°C) External probe -40 to 212°F (-40 to 100°C) Relative Humidity 0.0 to 99.9% |
Accuracy | Temperature: ±1°F (-4°F to 122°F); ±1.2°F for all others ±0.6°C (-20°C to 50°C); ±1.2°C for all others Relative Humidity: ±3% at 25°C / 77°F; 5% for all others |
Sensor | Silicon photodiode and filter |
Altitude | 2000 m, indoor operation |
Power Supply | 1 x 3V coin battery IEC-CR2032 |
Battery Life | 2-years with 7200-sec sampling rate |
Dimensions | 2.95 x 2.16 x 0.9" (75.5 x 53 x 23.5 mm) |
Weight | 0.044 lbs (0.02 kg) |
Display | 3¾ digit liquid crystal display (LCD) with a maximum reading of 1999 |
Sampling points | 1 K / 2 K / 4 K / 8 K / 12 K / 16 K |
Resolution | Temperature 0.1°C / 0.1°F RH Resolution 0.1% |
LED | Red: Hi, LO Alarm Yellow: Record |
Low Battery Indication | The "Batt" is displayed when the battery voltage drops below the operating level |
Auto Power Off | Approximately 10 minutes |
Operating Environment | 14 to 140°F (-10 to 60°C), 0 to 100% RH |
Storage Temperature | -40 to 185°F (-40 to 85°C), 0 to 100% RH |
Measurement Ranges | Temperature Internal sensor -40 to 185°F (-40 to 85°C) External probe -40 to 212°F (-40 to 100°C) Relative Humidity 0.0 to 99.9% |
Accuracy | Temperature: ±1°F (-4°F to 122°F); ±1.2°F for all others ±0.6°C (-20°C to 50°C); ±1.2°C for all others Relative Humidity: ±3% at 25°C / 77°F; 5% for all others |
Sensor | Silicon photodiode and filter |
Altitude | 2000 m, indoor operation |
Power Supply | 1 x 3V coin battery IEC-CR2032 |
Battery Life | 2-years with 7200-sec sampling rate |
Dimensions | 2.95 x 2.16 x 0.9" (75.5 x 53 x 23.5 mm) |
Weight | 0.044 lbs (0.02 kg) |