Detect CO2 with this wall-mounted single-gas detector that features a 0 to 9999 ppm range and temperature and humidity measurements. In addition, this detector has a built-in alarm to warn against dangerous CO2 levels and measures air quality compliance in critical controlled areas such as laboratories and production.
Detect CO2 with this wall-mounted single-gas detector that features a 0 to 9999 ppm range and temperature and humidity measurements. In addition, this detector has a built-in alarm to warn against dangerous CO2 levels and measures air quality compliance in critical controlled areas such as laboratories and production.
Features
Measuring Range | CO2 0 to 9999 ppm 2001 to 9999 ppm (out of scale range) |
Resolution | 1 ppm - CO2 concentration, 0.1°C / °F - Temp, 0.1% RH - Humidity |
Accuracy | ±75ppm±5% of reading (0 to 2000 ppm) Others range accuracy are not specified |
Temperature | ±0.9°F (±0.6°C) Range: 14°F to 140°F (-10°C to 60°C) |
RH Range | 0% to 95% |
Accuracy | ±3% RH (at25°C, 10 to 90%) others ±5% for other RH range |
DP (Dew Point Temperature) | -4°F to 139.8°F (-20°C to 59.9°C) |
WB (Wet Bulb Temperature) | 23°F to 139.8°F (-5°C to 59.9°C) |
Warm-up Time | 30 seconds |
Response Time | About 30 seconds |
Current Consumption | < 50 mA average, < 310 mA peak current (55 ms) |
Conditions | Operating: 32°F to 122°F (0 to 50°C), 0 to 95% RH (avoid condensation) for CO2 Storage: -4°F to 140°F (-20°C to 60°C), 0 to 99% RH (avoid condensation) |
Power Supply | 12 VDC adaptor |
Dimensions | 5.1 x 3.3 x 2.4" (130 x 85 x 60 mm) |
Weight | Approximately 0.43 lbs (193 g) |
Measuring Range | CO2 0 to 9999 ppm 2001 to 9999 ppm (out of scale range) |
Resolution | 1 ppm - CO2 concentration, 0.1°C / °F - Temp, 0.1% RH - Humidity |
Accuracy | ±75ppm±5% of reading (0 to 2000 ppm) Others range accuracy are not specified |
Temperature | ±0.9°F (±0.6°C) Range: 14°F to 140°F (-10°C to 60°C) |
RH Range | 0% to 95% |
Accuracy | ±3% RH (at25°C, 10 to 90%) others ±5% for other RH range |
DP (Dew Point Temperature) | -4°F to 139.8°F (-20°C to 59.9°C) |
WB (Wet Bulb Temperature) | 23°F to 139.8°F (-5°C to 59.9°C) |
Warm-up Time | 30 seconds |
Response Time | About 30 seconds |
Current Consumption | < 50 mA average, < 310 mA peak current (55 ms) |
Conditions | Operating: 32°F to 122°F (0 to 50°C), 0 to 95% RH (avoid condensation) for CO2 Storage: -4°F to 140°F (-20°C to 60°C), 0 to 99% RH (avoid condensation) |
Power Supply | 12 VDC adaptor |
Dimensions | 5.1 x 3.3 x 2.4" (130 x 85 x 60 mm) |
Weight | Approximately 0.43 lbs (193 g) |